EasyManua.ls Logo

Rosslare AYC-F54 - Page 21

Rosslare AYC-F54
62 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Reader Operation
AYC-F/Gx4 Series Installation and Programming Manual 21
3. Enter one of the following codes:
1Single Key, Wiegand 6-Bit (Rosslare Format) (default)
2Single Key, Wiegand 6-Bit with Nibble + Parity Bits
3Single Key, Wiegand 8-Bit, Nibbles Complemented
44 Keys Binary + Facility Code, Wiegand 26-Bit
51 to 5 Keys + Facility Code, Wiegand 26-Bit
66 Keys BCD and Parity Bits, Wiegand 26-Bit
7Single Key, 3x4 Matrix Keypad
81 to 8 Keys BCD, Clock & Data Single Key
When selecting Option 8, the Program LED turns orange,
awaiting an additional key input to select the number of keys.
You hear three beeps.
The system returns to Standby mode.
If an incorrect option number is entered, the reader returns to
Standby mode and the keypad transmission format remains
unchanged.
4.2.3.1 Single Key, 6-Bit Wiegand (Rosslare Format)
Each key press immediately sends 4 bits with 2 parity bits added
even parity for the first 3 bits and odd parity for the last 3 bits.
0= 1 1010 0 ="A" in Hexadecimal 6= 1 0110 0
1= 0 0001 0 7= 1 0111 1
2= 0 0010 0 8= 1 1000 1
3= 0 0011 1 9= 1 1001 0
4= 1 0100 1
= 1 1011 1 ="B" in Hexadecimal
5= 1 0101 0 #= 0 1100 1 ="C" in Hexadecimal
Red

Table of Contents

Other manuals for Rosslare AYC-F54

Related product manuals