EasyManuals Logo

Rotary 300 Series User Manual

Rotary 300 Series
12 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #8 background imageLoading...
Page #8 background image
8
Trouble
Electric motor does not run.
Electric motor runs but will not
raise lift.
The lift does not stop 9″ (250mm)
fromtheoorbutkeepslowering,
producing a warning signal during
the lowering phase.
Cause
1. Check fuse or circuit breaker.
2. Check for correct voltage to motor.
3. Inspect all wiring connections.
4. Faulty motor contactor.
5. Blownfuseon24Vpowersupply.
6. Faulty Transformer.
7. The motor thermic switch is
activated from overheating.
1. Motor runs in reverse rotation.
2. Load too heavy.
3. Lowuidlevel.
4. One or both manual operators
(A1-B1) on the hydraulic block
are open.
5. The lowering valve gaskets or
hydraulic block gaskets are
damaged or loose.
6. One or both manual operators
(A2-B2) on the hydraulic block
are open.
7. Oil filter is clogged.
8. Faulty hydraulic pump.
1. Faulty or improperly installed
proximetry.
Remedy
1. Replace blown fuse or reset
circuit breaker.
2. Supply correct voltage to motor.
3. Repair and insulate all connec-
tions.
4. Check the contactor coil opera-
tion and make sure it is activated
whensuppliedwith24V.
5. Check the fuse on the transform-
er and replace it if necessary.
6. Check the output voltage of the
transformer:
OUT:24V
7. Wait for 10 minutes and try start-
ing again; then, using a tester
make sure contact is closed
again.
1. Switch the phase and make
sure motor turns in the direction
indicated by the arrow.
2. Check vehicle capacity.
3. Fill tank with Dexron III ATF or
ISO32.
4. Close manual operators.
5. Check the gaskets and replace if
necessary.
6. Check and tighten screws.
7. Check and clean.
8. Check that oil comes out from
one of the A-1 - A-2 outlets on
the hydraulic block after discon-
necting the corresponding pipe.
Replace the pump if oil does not
come out from A-1 - A-2 outlets.
1. Check the proximetry and re-
place it if necessary.
TROUBLE SHOOTING

Other manuals for Rotary 300 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rotary 300 Series and is the answer not in the manual?

Rotary 300 Series Specifications

General IconGeneral
BrandRotary
Model300 Series
CategoryScissor Lifts
LanguageEnglish

Related product manuals