Semi-Annually: Check fluid level in hydraulic
reservoir.
Fluid Level Checking Procedure:
1. Completely lower rolling jack.
2. Disconnect air supply.
3. Wipe reservoir clean to prevent contamination of
fluid.
4. Remove fill plug and check fluid level. Fill as
required to bottom of fill hole with Mobil DTE 11 oil
hydraulic fluid. Take care to prevent contamination
during filling operation.
5. Reinstall plug hand tight only.
Note: Repair/Replace as required with original
equipment parts.
WARNING
If you are not completely familiar
with automotive lift maintenance procedures
STOP: Contact factory for instructions.
TO AVOID PERSONAL INJURY, permit only qualified
personnel to perform maintenance on this
equipment.
Daily: Inspect rolling jack adapters for damage or
excessive wear. Replace as required with original
parts.
Daily: Inspect air/hydraulic system for leaks.
Daily: Inspect for loose bolts, broken/damaged
components.
Daily: Inspect linkage curtain guard for damage,
wear and tear. Replace as required with original
parts.
Monthly: Inspect the roller assemblies.