EasyManua.ls Logo

ROTORCOMP EVO28 - 6.4 Recommissioning screw compressor air end system

Default Icon
36 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
ROTORCOMP VERDICHTER Operating Manual - EVO
®
Line
6.2 [en] 07/2020
6.4 Recommissioning screw compressor
air end system
Screw compressor air end systems switched off,
shut-down or stored for longer than three months
cannot be put into operation again until after the
following measures have been carried out:
Rotate the screw compressor air end in the
direction of rotation several times by hand.
With the screw compressor air end system at a
standstill, pour 0.53 to 2.1 quarts (0.5 to 2 liters)
of oil (same oil type as in the oil separator tank)
into the air intake after removing the intake filter
or manifold, depending on the compressor size
and the system.
Rotate the screw compressor air end again in
the direction of rotation several times by hand.
Check the oil level in the separator tank and top
up if necessary (see chapter 7 "Maintenance").
Test the running check function for the screw
compressor air end system for at least
15 minutes.
Warning:
The system may not be started with the feed
chamber completely filled. There is a danger of
considerable damage.
Maintain appropriate safety distance.
Here is a risk of injury if the rotors are blocked.
For safety reasons, only drive for a few seconds
during initial startup. Operation in open state must
not be carried out ear ear protection.