EGG STATION (ES-1200)
10
A.J. Antunes & Co.
P/N 1011119 Rev. B 03/12

NOTE: A pyrometer is required for this procedure.
1. Turn the power on and allow 30 minutes for the
unit temperature to stabilize.
2. Using a pyrometer, measure the temperature at
the middle of the Platen surface (Figure 2). The
temperature should be approximately ±15°F of
350°F (177°C).
If temperature is within range, proceed to Step 3.
If temperature is above or below range, call your
Authorized Service Agency.
3. Turn the off the power and allow unit to cool.
WARNING



MAINTENANCE (continued)