14
NOVA 3
®
Failure to supply the minimum required air pressure at the point of
attachment for the length of air supply hose will decrease the level of
protection provided. In addition, could result in contaminants being inhaled as the pressure in the
helmet may become negative due to peak inhalation ow when working at very high work rates.
Low airow will decrease the level of protection provided.
1. AIR SOURCE 2. AIR SUPPLY
HOSE
3.
NV2021B
BREATHING TUBE
ASSEMBLY AND
FLOW CONTROL
DEVICES
4. SUPPLY
HOSE LENGTH
(FT)
5. MAX
NUMBER OF
SECTIONS
6.
PRESSURE
RANGE
(PSIG)
NV2016 Flow
Control Valve
Assembly with
Schrader Fitting
25
50
100
150
200
250
300
1
1
2
3
4
5
6
28-30
30-32
33-35
36-38
40-42
44-46
48-50
4000-01 Climate
Control Tube
Assembly with
Schrader Fitting
25
50
100
150
200
250
300
1
1
2
3
4
5
6
60-65
60-65
65-70
70-75
75-80
80-85
85-90
4000-20 Climate
Control Tube
Assembly with
Schrader Fitting
25
50
100
150
200
250
300
1
1
2
3
4
5
6
70-75
70-75
75-80
80-85
85-90
90-95
95-100
03-500 C40
Climate Control
Tube Assembly with
Schrader Fitting
25
50
100
150
200
250
300
1
1
2
3
4
5
6
60-80
65-85
70-95
75-95
80-100
85-100
95-100
WARNING
BREATHING AIR PRESSURE TABLE CONTINUED
Portable or
Stationary
Compressor
04-342-25 (25ft)
04-342-50 (50ft)
04-342-100 (100ft)