OPERATION
AIR PRESSURE
AIR TEMPERTURE
AIR QUALITY
AIR CONNECTIONS
The air pressure supplied to the Radex Airline Filter should not exceed 125psi (860 kpa).
When setting the outlet pressure using the pressure regulator refer to your respirator instruction
manual to set the correct air pressure.
The Air supplied to the Radex Airline Filter should not exceed 140 degrees Fahrenheit
(60 degrees Celsius). Do not connect the Radex Airline Filter directly to the compressor outlet
manifold.
The Radex Airline Filter does not remove carbon monoxide and other toxic gases from the
breathing air supply. A Radex carbon monoxide monitor 08-200 must be used at all times.
Supplied air passing through this Radex Airline Filter must meet the requirements of Grade D.
EN12021 or AS/NZS 1715 refer to your relevant authorities for copies of these standards.
Regular tests of the compressed air must be carried out to ensure it meets the requirements for
breathable air.
Connect air fittings that meet the requirements of OSHA for respirable air. The inlet thread size is
1” NPT. All connections should be sealed using liquid thread sealant. If the Radex Airline Filter is
hard piped an isolation valve must be used to enable depressurisation for servicing.