STARTING PROCEDURES
Insert key hexagon into the groove turning anti-clockwise to “OPEN”
Insert key into ignition, turn to ON position.
Make sure the transmission is in the NEUTRAL position.
Turn the engine stop switch to RUN.
If you are restarting a warm engine, follow procedure for High Air Temperature.
Normal Air Temperature: 10º -35ºC (50º -95ºF)
Starting and Stopping the Engine
High Air Temperature: 35ºC (95ºF) or above
1) Slightly open throttle
2) Start engine
Low Air Temperature: 10ºC (50ºF) or below
1) Follow Normal Air Temperature procedures 1-2.
2) RPM is automatically adjusted by ECU.
3) Keep warming the engine until it responds to the throttle.
NOTICE:
Fast idling for more than 5 minutes at Normal Air Temperature can cause exhaust
pipe discoloration.
Flooded Engine
The engine may be flooded with extra gasoline, if it does not start after several
attempts. Try the following to clear a flooded engine:
1) Turn the engine stop switch to the OFF position.
2) Open the throttle completely.
3) Push and hold in the start button for 5 seconds.
4) Wait 10 seconds and turn the engine stop switch to the RUN position.
Next, follow the High Air Temperature starting procedures.