Heat Dissipation
The RG-S2928G-24P switch adopts axial fans for heat dissipation, thereby ensuring the device to function normally in the
specified environment. Sufficient space (10 cm distance from both sides and the back panel of the chassis) should be
reserved for ventilation. Dust the device every three months to avoid blocking the ventilation openings.
Figure 1-16 Heat Dissipation of the RG-S2928G-24P
When installing the device, sufficient ventilation space (1 U (44.45 mm) distance from the adjacent device) should be
reserved for the purpose of heat dissipation.
PoE
The PoE power supply of the RG-S2928G-24P switch is designed to support the IEEE802.3af and 802.3at standards. It
uses Alternative A, that is, uses pins 1&2 and 3&6 to transmit power.
LED Indicators
Serious over-temperature, the system
will stop working forcibly by itself. Or the
fan fault occurs.