MODEL 51240B/53540B/53640B/61240B/63540B/63640B
2
be installed before the water inlet. While, if the water pressure under
0.2MPa, a diaphragm pump must be installed before the water inlet.
It is suggested to install PPR pipe, corrugated pipe or UPVC pipe,
instead of TTLSG pipe.
Do not let children touch or play, because carelessness operating may
cause the procedure changed.
When the attached cables of this product and transformer are changed,
they must be changed to the one that is from our factory.
1. Product Overview
1.1. Main Application & Applicability
Used for softening, demineralization or filtration water treatment systems
51240B/53540B/53640B (Filter)
Suit for swimming pool filter equipment
Filtration equipment
RO pretreatment active carbon and sand filtration system
61240B/63540B/63640B (Down-flow softener regeneration)
Suit for the ion exchange equipment which hardness of the raw water
≤6.5mmol/L
Boiler softening water system
RO pretreatment softening system
1.2. Product Characteristics
Simple structure and reliable sealing
The distribution valve adopts hermetic head faces with high degree
pottery and corrosion resistance for opening and closing. It combines with
Service, Backwash, Brine Draw, Slow Rinse, Fast Rinse and Brine Refill.
No water passes the valve during regeneration in single tank
type.
Brine refilling is controlled by electric ball valve.