MODEL: 63518-N77A1 /63618-N77A3/ 53518-N77B1
15
Resin
Volume
50L.
5000L.
20500L.
Resin volume in brine tank (L)
Feed
Water
Hardness
Yd1.2
1.2
0.19.9
Feed water hardness (mmol/L)
Exchang
e Factor
AL.65
0.65
0.300.99
Relate to the raw water hardness.
When hardness is higher, the
factor is smaller.
Water
Treatmen
t
Capacity
80 m
3
0999.99 m
3
Water treatment capacity in one
circle (m
3
)
Backwas
h Time
10 min.
099
Backwash time (Minute)
Brine &
Slow
Rinse
Time
60 min.
099
Brine &Slow rinse time (Minute)
Brine
Refill
Time
5 min.
099
Brine refill time (Minute)
Fast
Rinse
Time
10 min.
099
Fast rinse time (Minute)
Maximum
Interval
Regener
ation
Days
H-30
30
040
Regenerate on the day even
through the available volume of
treated water do not drop to zero
(0).
Output
Control
Mode
b-01
01
01 or 02
Mode 01: Signal turn on start of
regeneration and shut off end of
regeneration. (Connection refer to
the Figure on P3)
Mode 02: Signal available only
intervals of regeneration cycles
and in service. (Connection refer
to the Figure on P3)