EasyManua.ls Logo

Runxin N77A3 - Page 2

Default Icon
51 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
MODEL: 63518-N77A1 /63618-N77A3/ 53518-N77B1
Before the valve put into use, please fill in the below content so as to
help us to refer in the future.
Softener System Configuration
Tank Size:Dia. mm,Height mm;
Resin Volume L;Brine Tank Capacity L;
Hardness of Raw Water mmol/L;
Pressure of Inlet Water MPa;
Control Valve Model ;Number ;
The Specification of Drain Line Flow Control ;
Injector No. .
Water Source: Ground-water□ Filtered Ground-water □Tap Water □
Other .
Parameter Set
Parameter
Unit
Factory
Default
Actual
Value
Control Mode A-01(02,03,04)
/
A-01
Water Treatment Capacity(Meter type)
m
3
80
Service Days(Time clock type, by days)
D.
03
Service Hours(Time clock type, by hours)
H.
20
Regeneration Time
/
02∶00
Backwash Time
min.
10
Brine & Slow Rinse Time
min.
60
Brine Refill Time
min.
05
Fast Rinse Time
min.
10
Interval Regeneration Days
D.
30
Output Mode b-01(02)
/
b-01
●If there is no special requirement when product purchase, we choose
3# drain line flow control and 3# injector for the standard configuration.