9.0 DIAGNOSTICS & TROUBLESHOOTING
Diagnostics
EcoNet Fault Code Response Action
A001_O Model Data Conguration Error Disabled while active
A002_O Compressor Model Data Error Disabled while active
A003_O Fan Model Data Error Disabled while active
A004_O EcoNet Thermostat Version Not Compatible Disabled while active
A093_O Model Data Restore Failure Disabled while active
A111_O Communications Lost with Indoor Unit Disabled while active
A112_O: Expected EcoNet IDU not connected Disabled while active (Regal Beloit and Emerson only)
A811_O Inverter - IPM Fault 3-strikes, permanent lockout
A812_O Inverter - Drive Failure 3-strikes, permanent lockout
A813_O Inverter - IPM Sampling Fault 3-strikes, permanent lockout
A814_O Inverter - AC Input Sampling Fault 3-strikes, permanent lockout
A815_O Inverter - Fan 1 Fault 3-strikes, permanent lockout
A816_O Inverter - Fan 2 Fault 3-strikes, permanent lockout
A817_O Inverter - Rect. Bridge Temp Sensor 3-strikes, permanent lockout
A818_O Inverter - Logic Board Comm Fault 3-strikes, permanent lockout
A819_O Inverter - DC Overvoltge Logic Fault 3-strikes, permanent lockout
A821_O Inverter - DC Undervoltage Logic Fault 3-strikes, permanent lockout
A822_O Inverter - Rect. Bridge Overtemp Fault 3-strikes, permanent lockout
A823_O Inverter - AC Overrvoltage Logic Fault 3-strikes, permanent lockout
A824_O Inverter - Compressor Reversed Connection 3-strikes, permanent lockout
A825_O Inverter - AC Input Overcurrent 3-strikes, permanent lockout
A826_O Inverter - AC Input Phase Fault 3-strikes, permanent lockout
A827_O Inverter IPM Temp Sense Failure Disabled while active
A828_O Inverter EEPROM Failure Disabled while active
A912_O Inverter Fault - Self-Check Fault Disabled while active
A915_O Inverter Fault - Comm Fault Shutdown, restart upon clearing
A920_O Inverter Fault - PFC Desaturation Shutdown, restart upon clearing
A924_O Inverter Fault - Board Temp Shutdown, restart upon clearing
A925_O Inverter Fault - Comp. Model Unknown Disabled while active
A926_O Inverter Fault - HP Sensor Not Congured Disabled while active
A927_O Inverter Fault - Drive Conguration Disabled while active
A928_O Locked Out - See History Faults Permanent lockout
A929_O 240V Missing or Inverter Comm Failure Disabled while active
A948_O Inverter Fault - AC Input Overvoltage Shutdown, restart upon clearing
A949_O Conguration Data Restore Failure Disabled while active
A950_O Conguration Data Restore Failure Disabled while active
A953_O Coil Temp Thermistor Failure algorithms default
A954_O Suction Temp Thermistor Failure algorithms default
A956_O Suction Pressure Sensor Failure algorithms default
A957_O Low Refrigerant Pressure 4 hour lockout
A958_O High Refrigerant Pressure 4 hour lockout
A960_O Compressor Locked Rotor - Lockout Disabled while active
A962_O Compressor U-Phase Over Current 3-strikes, permanent lockout
A963_O Inverter Fault - AC Input Undervoltage Shutdown, restart upon clearing
A966_O Inverter Fault - Lost Rotor Position 3-strikes, permanent lockout
A969_O Loss of Discharge Temperature Protection Disable when active
A970_O Inverter/Compressor Mismatch Disabled while active
A972_O: Compressor Discharge Temp High at Min RPM Disabled while active
A975_O Contactor Stuck On Shutdown, restart upon clearing
A979_O Compressor Over/Under Speed Shutdown, restart upon clearing
A985_O Fan Self Check Fault Disable when active
A987_O Compressor Loss of Phase 3-strikes, permanent lockout
A988_O Compressor Control Lost 3-strikes, permanent lockout
A989_O Charge Relay Open 3-strikes, permanent lockout
A991_O Compressor V-Phase Over Current 3-strikes, permanent lockout
A992_O Compressor W-Phase Over Current 3-strikes, permanent lockout
A993_O Compressor Module Over Current 3-strikes, permanent lockout