EasyManua.ls Logo

Ruud RP1442FC1NA - User Manual

Ruud RP1442FC1NA
56 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
R-410A HEAT PUMP
OUTDOOR UNITS
92-105074-04-03 (8/15)
Printed in USA
[ ] indicates metric conversions.
Do not destroy this manual.
Please read carefully and
keep in a safe place for future
reference by a serviceman.
WARNING
THESE INSTRUCTIONS
ARE INTENDED AS AN AID
TO QUALIFIED, LICENSED
SERVICE PERSONNEL FOR
PROPER INSTALLATION,
ADJUSTMENT, AND
OPERATION OF THIS UNIT.
READ THESE INSTRUCTIONS
THOROUGHLY BEFORE
ATTEMPTING INSTALLATION
OR OPERATION. FAILURE
TO FOLLOW THESE
INSTRUCTIONS MAY RESULT
IN IMPROPER INSTALLATION,
ADJUSTMENT, SERVICE,
OR MAINTENANCE
POSSIBLY RESULTING IN
FIRE, ELECTRICAL SHOCK,
PROPERTY DAMAGE,
PERSONAL INJURY, OR
DEATH.
INSTALLATION INSTRUCTIONS
RP13 (13 SEER)
RP14 (14 SEER) AND RP15 (15 SEER)
WARNING:
RECOGNIZE THIS SYMBOL
AS AN INDICATION OF
IMPORTANT SAFETY
INFORMATION
Question and Answer IconNeed help?

Do you have a question about the Ruud RP1442FC1NA and is the answer not in the manual?

Summary

Important Safety Information

Specifications

Proper Installation

Emphasizes correct installation for optimal performance and energy efficiency.

Installation

Choosing a Location

Guidance on selecting an outdoor unit location for longevity and service.

Factory-Preferred Tie-Down Method for High Wind or Seismic Loads

Tools and Refrigerant

Interconnecting Tubing

Refrigerant Level Adjustment

Explains how to adjust refrigerant charge based on line set length and elevation.

Liquid Line Selection

Guides on selecting the proper liquid line size to prevent flashing and ensure efficiency.

Suction Line Selection

Explains proper suction line sizing for oil return and system performance.

Tubing Installation

Guidelines for installing refrigerant tubing between units, including size and material.

Tubing Connections

Instructions for making brazed connections for copper refrigerant tubing.

Leak Testing

Procedure for leak testing the refrigerant lines and coil using nitrogen.

Wiring

Control Wiring

Explains low-voltage wiring for thermostats, transformers, and control circuits.

Power Wiring

Details voltage requirements and connection points for power wiring.

Grounding

Explains the necessity and procedure for proper unit grounding.

Start-Up

Start-Up

Procedures for initial system start-up, including crankcase heater operation.

Checking Airflow

Discusses airflow importance, calculation methods, and system balancing.

Evacuation and Leak Testing

Evacuation Procedure

Details the process of removing air and moisture from the system.

Final Leak Testing

Explains how to check for leaks after evacuation using a leak detector.

Checking Refrigerant Charge

Gross Charging by Pressures

Details how to perform gross charge adjustment using pressures.

Final Charge by Subcooling

Explains the final charge adjustment procedure using subcooling.

Demand Defrost Control

Diagnostics

General Troubleshooting Chart

A chart listing symptoms, possible causes, and remedies for common issues.

Wiring Diagrams

Ruud RP1442FC1NA Specifications

General IconGeneral
ModelRP1442FC1NA
TypeHeat Pump
SEER Rating14
HSPF Rating8.2
RefrigerantR-410A
Voltage208/230V
Phase1
Compressor TypeScroll
Sound Level (Outdoor Unit, dBA)76
Unit Weight (lbs)260
Cooling Capacity42000 BTU/h
Heating Capacity42000 BTU/h

Related product manuals