CHARGE PLUS Models CBHF1SM, CBHF1-V2, CBHF2 Page 10 of 12
USERS MANUAL
FAULTS AND TROUBLESHOOTING
PROBLEMS
SOLUTIONS AND CHECKS
THE BATTERY CHARGER DOES NOT
SWITCH ON.
CHECK THAT THE A/C AND D/C PLUGS
ARE CONNECTED AND THAT THE A/C
OUTLET IS RECEIVING POWER.
THE CHARGING CYCLE DOES NOT
START AND THE MESSAGE “bat IS
DISPLAYED.
CHECK THE CONNECTION TO THE
BATTERY AND THE POLARITY.
THE YELLOW INDICATOR (4) WILL NOT
LIGHT UP EVEN AFTER 15 HOURS
FROM THE STARTING OF THE CHARGE
CYCLE AND THE DISPLAY SHOWS
“E03”.
CHECK THE BATTERY FOR POSSIBLE
FAULTY COMPONENTS.
THE MESSAGE E01” IS DISPLAYED.
THIS MEANS THAT THE MAXIMUM
VOLTAGE ADMISSIBLE BY THE
BATTERY HAS BEEN EXCEEDED. THE
CHARGING IS INTERRUPTED.
IF THE BATTERY CHARGER IS
PROVIDED WITH A SAFETY
THERMOSTAT AND THE MESSAGE
“E02” IS DISPLAYED.
THIS MEANS THAT THE MAXIMUM
TEMPERATURE HAS BEEN EXCEEDED.
THE CHARGING IS INTERRUPTED.
THE MESSAGE E03” IS DISPLAYED.
THIS MEANS THAT THE MAXIMUM TIME
FOR THE CHARGING PHASE HAS BEEN
EXCEEDED. THE CHARGING IS
INTERRUPTED.
THE MESSAGE SCt” IS DISPLAYED.
THIS MEANS THAT THE TOTAL SAFETY
TIMER HAS INTERRUPTED THE
CHARGING.
THE MESSAGE Srt” IS DISPLAYED.
THIS SIGNALS A POSSIBLE INTERNAL
SHORT CIRCUIT. THE UNIT WOULD
NEED TO BE SENT TO A REPAIR
CENTER.