EasyManua.ls Logo

Sabiana SK 12 User Manual

Sabiana SK 12
84 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Via Piave, 53 20011 Corbetta (MI) ITALY
Tel. +39.02.97203.1 ric. autom. Fax +39.02.9777282 - +39.02.9772820
E-mail: info@sabiana.it Internet: www.sabiana.it
MANUALE DI INSTALLAZIONE,
USO E MANUTENZIONE DEI VENTILCONVETTORI
CASSETTE SKYSTAR
-
ECM
FAN COIL CASSETTE SKYSTAR
-
ECM INSTALLATION,
USE AND MAINTENANCE MANUAL
MANUEL D’INSTALLATION, D’UTILISATION
ET D’ENTRETIEN DES VENTILO-CONVECTEURS
CASSETTE SKYSTAR
-
ECM
HANDBUCH FÜR INSTALLATION,
GEBRAUCH UND WARTUNG
DER KASSETTEN-KLIMAKONVEKTOREN SKYSTAR
-
ECM
MANUAL DE INSTALACIÓN, USO Y MANTENIMIENTO
DE LOS VENTILADORES CONVECTORES
CASSETTE SKYSTAR
-
ECM
HANDLEITUNG VOOR DE INSTALLATIE, HET GEBRUIK
EN HET ONDERHOUD VAN DE VENTILATORS-CONVECTORS
CASSETTE SKYSTAR
-
ECM
S 03/19
E 03/19
Cod. 4050090
SK
ECM

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Sabiana SK 12 and is the answer not in the manual?

Sabiana SK 12 Specifications

General IconGeneral
BrandSabiana
ModelSK 12
CategoryAir Conditioner
LanguageEnglish

Summary

SkyStar ECM Fan Coil Manual

Introduction to Operation and Safety

Important and Dangerous Operations

Highlights operations requiring special attention or caution due to risk.

Personnel Qualifications for Operations

Specifies that operations must be performed by trained users or authorized technicians.

Product Application and Usage Limits

Prohibited Installation Environments

Lists environments and uses where the unit must not be installed or operated.

General Safety Warnings and Precautions

Critical Work Areas & Personnel Qualifications

Outlines critical work areas and required qualifications for personnel.

Electrical & Hydraulic Work Qualifications

Specifies required qualifications for electrical and hydraulic work.

Scope of Manual and Personnel Qualifications

Qualified Personnel for Repairs and Installation Work

States that all repairs and installation must be performed by qualified specialists with relevant training.

Installation & Repair Work Qualifications

Details the necessary training and familiarity with standards for skilled workers.

Installation Precautions and Procedures

Pre-installation Safety Checks

Lists essential steps before installation, including removing fan lock and installing safety features.

Prohibited Installation Locations

Warns against installing the unit in explosive, corrosive, damp, or dusty environments.

Handling and Lifting Safety Guidelines

Outlines safe practices for handling the unit, including lifting requirements and load safety.

Maintenance and Repair Procedures

Product Operating Limits and Disposal

Fan Coil & Heat Exchanger Limits

Specifies operational limits for the fan coil and heat exchanger.

Technical Data and Specifications

Hydraulic Connection Configurations

Details the hydraulic connection types for 2-pipe and 4-pipe systems.

Installation Procedures and Requirements

Mechanical Installation Procedures

Appliance Positioning and Fixing Method

Guides on positioning the appliance to avoid intake obstruction and fixing it using threaded rods.

Installation Procedure Steps

Details the steps for mechanical installation, including marking and drilling holes.

Further Installation Details

Unit Installation and Positioning

Covers tilting, positioning, securing, and leveling the unit during installation.

Hydraulic Connections Guide

Valve Connections and Characteristics

Electrical Connections and Safety

Controller Signal, Safety Features, Earthing

Explains controller signals, safety relays, overvoltage protection, and unit earthing.

Connection Instructions and Electrical Equipment Details

General Connection Instructions

Advises respecting wiring diagrams and using installer-provided access points.

Electrical Equipment Features

Details motor protection, terminal board functions, and cooling mode operation.

Wiring Diagram - Option 1

Wiring Diagram - Option 2

Controller Input Signals Explained

Shows the input signals for fan control and speed settings for Option 2.

Controller Application and Usage Limits

Controller Placement and Compliance

Specifies that the controller must be inside a metal panel to ensure compliance.

Required Controller Specifications

Lists essential specifications for controllers, including output signal and input impedance.

Temperature Sensors: NTC and T2 Probes

Electric Resistance Option Details

Electric Resistance Availability and Function

Details the electric resistance option for 2-pipe models, replacing the hot water valve.

Safety Thermostats and Reset Procedure

Explains the safety thermostats for over-temperature protection and the reset process.

Warnings and Safety Thermostats for Electric Heaters

Electric Heater Operation Warnings

Provides warnings about fan operation, airflow obstruction, and NTC probe usage with heaters.

Safety Thermostat Types and Operation

Details the safety thermostats, their functions, and how to identify and reset them.

Wiring Diagrams Overview

Main Wiring Diagram

Presents the primary electrical wiring diagram for the unit.

Installation with Installer-Provided Valves

Valve Installation and Condensate Prevention

Guides on installing installer-provided valves and preventing condensate leaks.

Cleaning, Maintenance, and Spare Parts

Filter Cleaning and Replacement Guide

Provides detailed instructions for cleaning or replacing the air filter.

IMPORTANT! Maintenance Safety Precautions

Emphasizes turning off power before any cleaning or maintenance activity.

Troubleshooting Common Malfunctions

Motor and Airflow Issues Resolution

Lists causes and remedies for motor problems and insufficient airflow.

Performance and Leakage Issue Resolution

Addresses unit performance problems (heating/cooling) and water leaks, providing solutions.

Maintenance Procedures

General Maintenance Guidelines

Covers using original parts, gloves, unplugging, and fan stoppage checks.

Electrical Safety During Maintenance

Warns about dangerous voltage and the need for capacitor discharge before work.

Filter Maintenance Procedures

Provides detailed instructions for cleaning or replacing the air filter.

Water Pressure Drop Tables

Detailed Technical Data Tables