MANUAL MACHINES 04 OPERATING LOGIC
SAECO Rev. 00 / May 2010 Page / 05
- COLD WATER
- HOT WATER/STEAM
- HOT WATER
WATER TANK
FLOW METER
BOILER
STOPCOCK
THERMOSTATS
HOT WATER/STEAM
DISPENSING PIPE
DISPENSING COFFEE
FILTER HOLDER
PUMP
OVERPRESSURE VALVE
4.1. Water circuit
01
Speci cations and requirements
Maximum pump operating pressure 15 bar
Maximum pressure in the water/steam circuit does not exceed 15 bar
Hot water temperature 90°C
Steam temperature 125°C
Max coffee thermostat 95°C
Max steam thermostat 127°C
Max thermal protector thermostat 184°C
Max overpressure valve 16/18 bar
P.S.: Only the single coffee machines have a ow meter, which can set and save the amount
of dispensed coffee via the control board.

Other manuals for Saeco Aroma

Questions and Answers:

Saeco Aroma Specifications

General IconGeneral
TypeEspresso Machine
Pump Pressure15 bar
Material BoilerStainless Steel
Hot Water / Steam NozzleYes
Removable Drip TrayYes
Cup WarmerYes
Compatible Coffee TypeGround coffee