INTEGRA/-S/-G/-GS User Manual INSTALLATION
SAF Tehnika JSC
11
1
Remove Integra/Integra-G FODU with an
antenna from the mounting bracket.
The default polarization is vertical.
2
Using 13mm wrench remove indicated nuts
and fixation plate [10, 11, 12, 13, 14].
3
Removed parts must be attached back with
a 90-degree offset (see above). The gap
between side screw flange nuts [13] and
fastening angles should be 5mm.
4
View of Integra/Integra-G FODU with
swapped polarization.
5
When polarization is changed, make sure
that the drain hole cap located at the
grounding flange nut is removed and
inserted into the previous drain hole.