Most used parameter list
- for full list see installation manual
Conguration Code Data Comments
Entercongurationmode 00
Enter password * - - - - # Default = 0000
Exitcongurationmode *00*#
Alarm Code Data Comments
P100 ID code *01* - - - - - - - - # P100isalways8digits
CPC ID code *02* - - - - - - # CPC6-8digits
Q23 ID code *03* - - - - - - - - -- - # Q23 is always 12 digits
Telephone numbers Code Data Comments
1st Phone number *11* - - - - - - - - - #
Phone number to alarm receiver: 1-20
digits.
Each asterisk (*) is equal to one
second delay.
Example #1: *11*0**1234567#
Example #2: *11*# deletes the phone
number.
2nd Phone number *12* - - - - - - - - - #
3rd Phone number *13* - - - - - - - - - #
4th Phone number *14* - - - - - - - - - #
Call type Code Data Comments
Call type 1st number *21* - # 0 = P100
1 = VOICE (default)
2 = Q23
3 = CPC
Call type 2nd number *22* - #
Call type 3rd number *23* - #
Call type 4th number *24* - #
Call type LMS number *30* - # 0 = P100
3 = CPC (Only battery alarm)
Test alarm/battery alarm Code Data Comments
LMS phone number *16* - - - - - - - - - # LMS (Lift Monitoring System) phone number
to alarm receiver or SLCC.
Test alarm *17* - - - - - - - - - # Phone number to test alarm receiver or
SLCC.
Days between tests *27* - - # Number of days between test alarms, 00-99
days.
Always two digits.
Test alarm protocol *31* - # 0 = P100
3 = CPC
4 = Caller ID