Other codes Code Data Comments
Emergency signal in speaker *71* - # The speaker siren will sound at emergency call.
0 = Off (default)
1 = On
Additional input function *73* - # Selects input function:
0 = None (Default)
1 = Filter, blocks the alarm input when active.
2 = LMS (Lift Monitoring System), sends a lift
monitoring alarm at input activation.
3 = Clear/Maintenance
4 = Call Delay
Additional input type *74* - # 0 = Normally-open contact, N/O (Default)
1 = Normally-closed contact, N/C
Indicator mode *78* - # 0 = Standard (default)
1=StrictlyEN81-28
2=StrictlysingleEN81-28
Unit number *82* - # Unit number [0] is set by default, and means that
the unit will respond immediately.
Unit number [1-9] is used when the units are
sharing the same phone line. When the unit
numberisassigned,thespeciedunitisaccessible
forconguration.
Alarm button delay time *87* - - # Delay time from pressing the alarm button until
activating the alarm.
00-25 seconds. Default = 05
Alarm button type *89* - # 0 = Normally-open contact, N/O (Default)
1 = Normally-closed contact, N/C
Change password *91* - - - - # Change password (default=0000).