The corresponding configuration keys are in file /cfg/Wiegand in either
section IN or OUT:
26-bit: default format
/Length: 26
/Start: 2.12 //even parity calculated over the first 12 bits
/Site: 1.8 //1-byte facility code inserted in first
/ID: 9.16 //2-byte ID inserted in second
/Custom: 0.0
/Stop: 3.12 //odd parity calculated over the last 12 bits
34-bit
/Length: 34
/Start: 0.0 //reset to 0
/Site: 1.16 //2-byte comparison number inserted in first
/ID: 17.16 //2-byte sequence number inserted in second
/Custom: 0.0
/Stop: 1.0 //set to 1
37-bit: HID format
/Length: 37
/Start: 2.18 //even parity calculated over the first 18 bits
/Site: 0.0
/ID: 1.35 //35-bit ID (max value is 4294967295)
/Custom: 0.0
/Stop: 3.18 //odd parity calculated over the last 18 bits