Use this signal to wait a controller “ACK” or to drive the terminal led.
LED IN signal
/cfg/Maccess/Wiegand/dataclock/
Led IN
0 (default) Active
The led in signal is ignored.
1 Inactive
The MorphoAccessTM led is driven by the led in signal:
led in = 0 led is green
led in = 1 led is off
2 The Wiegand in port is used as a dual led in port.
D1 is connected to Led in green and D0 to Led in red.
This feature improves integration in an access control system
(ACS). Result of biometric matching is validated by the ACS
through Led in signals.
When the ACS validates the control a timeout must be specified.
ACK timeout
/cfg/Maccess/Wiegand/dataclock/
Timeout
Time in seconds during which the
MorphoAccess™ will wait for an
acknowledgement signal from the ACS
through Led in signals.
(“Led IN 2“ mode).