BATTERY PANEL 13
Adjustment of High voltage alarm threshold for Battery 2:
1. Apply an input voltage set to the wanted threshold value to the
terminals ‘+ VBAT’ and ‘- VBAT’.
2. Adjust R94 (see figure pos. 3) until high battery alarm is indicated.
3. Decrease the input voltage by 0.5V and check that the alarm stops.
If not repeat the adjustment.
Adjustment of Low voltage alarm threshold for Battery 2:
1. Apply an input voltage set to the wanted threshold value to the
terminals ‘+ VBAT’ and ‘- VBAT’.
2. Adjust R95 (see figure pos. 4) until low battery alarm is indicated.
3. Increase the input voltage by 0.5V and check that the alarm stops.
If not repeat the adjustment.
INSTALLATION