H2-5K-T2 H2-6K-T2 H2-8K-T2 H2-10K-T2
1000
180~900
600
180
15 / 15
18 / 18
2
1/1
Lithium batte
180~600
30/30
7500 9000 12000 15000
5000
5000
5500
7.2
6000
6000
6600
8.7
8000
8000
8800
11.6
10000
10000
11000
14.5
MODEL
PV String Input
Max.PV Array Power [Wp]@STC
Max. DC Voltage [V]
MPPT Voltage Range [V]
Nominal DC Voltage [V]
Sta Voltage [V]
Max. DC Input Current [A]
Max. DC Sho Circuit Current [A]
No. of MPPT
No. of Strings per MPPT
Batte Input
Batte Type
Voltage
Range [V]
Max. Charging/ Discharging Current [A]
Rated Charging/ Discharging Power [W]
AC Output /Input Data(On-grid)
Rated AC Power [W]
Max. Apparent Power* [VA]
1
Rated AC Current [A]@230Vac
8.3
14.5 17.4 23.2 29.0
10.0 13.3 16.7Max. AC Current Output to Utility Grid [A]
Max. AC Current from Utility Grid [A]
220/ 380Vac, 230/ 400Vac, 3L/ N/ PE
50/ 60 ± 5
0.8 leading~0.8 lagging
<3%
220/ 380Vac, 230/ 400Vac, 3L/ N/ PE
50/ 60 ± 5
<3%
5000
8.0
10000, 60s
6000
9.6
12000, 60s
52
45
20.8 25 33.3 41.8
8000
12.8
16000, 60s
10000
15.9
16500, 60s
Current Inrush[A]
Max. AC Fault Current[A]
Max. AC Over Current Protection[A]
Nominal AC Voltage [V]
Rated Grid Frequency / Range [Hz]
Power Factor [cos φ]
Total Harmonic Distoion [THDi]
AC Output [Back-up Mode]
Max. Output Power [VA]
Max. Output Current [A]
Rated Output Voltage [V]
Rated Output Frequency [Hz]
Total Harmonic Distoion of Voltage
Peak Output Apparent Power [VA]
H2-5K/ 6K/ 8K/ 10K-T2
H2-5K-T2 H2-6K-T2 H2-8K-T2 H2-10K-T2
MODEL
Eciency
Max. Eciency
Euro Eciency
MPPT Eciency
Max. Batte Charging/ Discharging Eciency
Protection
AC Sho Circuit Protection
Overload Protection
Residual Current Monitoring Unit
Batte Input Reverse Polarity Protection
Anti-islanding protection
AC Surge Protection
DC Surge Protection
AFCI
Inteace
PV Connection Type
Batte Connection Type
AC Output
Display
Communication po
Comm
unication
General Data
Topology
Ingress Protection
Operating Temperature Range
Ambient Humidity
Altitude
Noise [dBA]
Cooling method
Dimensions [H*W*D][mm]
Weight [kg]
Standard Warranty [year]
Applicable Standard
98.0%
97.6%
>99.9%
97.6%
Integrated
Integrated
Integrated
Integrated
Integrated
Type III
Type III
Optional
MC4
Quick Connector
Plug-in Connector
LED+APP
CAN/ RS485/ DRM/ RS232
Wi-Fi/ Ethernet/ 4G (Optional)
Non-isolat
ed
IP65
-25°C to +60°C
0~100% No Condensing
4000m (>3000m power derating)
<30
Natural Convection
433*549*207
25
5
CEI 0-21, VDE4105-AR-N, VDE0126-1-1, EN50438, G98, G99, EN50549, AS4777.2
IEC62109-1&-2, IEC62040-1 , EN61000-6-1/2/3/4
*1 *
or Australia, Rated Apparent power[VA]:5000VA.6000VA.8000VA.10 000VA;

Other manuals for SAJ H2-10K-T2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SAJ H2-10K-T2 and is the answer not in the manual?

SAJ H2-10K-T2 Specifications

General IconGeneral
BrandSAJ
ModelH2-10K-T2
CategoryInverter
LanguageEnglish

Related product manuals