Light Commercial R410A on-off S13-01.01.13en
Notes: 1. Nominal cooling capacities are based on the following conditions:
Indoor temp: 27°CDB, 19°CWB; Outdoor temp: 35°CDB; Equivalent ref. Piping: 7.5m(horizontal)
2. Nominal heating capacities are based on the following conditions:
Indoor temp: 20°CDB; Outdoor temp: 7°CDB, 6°CWB; Equivalent ref. Piping: 7.5m(horizontal)
3. Actual noise level may differ, depending on the room structure, etc, since these noise values are from an anechoic
room.
Indoor Units. Ceiling & Floor 45
Model
SIB-200TAY
Power supply V-ph-Hz
380~415-3-50
Cooling
Capacity Btu/h
60000
Input W
5882
EER
2.72
Heating
Indoor fan motor
Model
YSK59-4D
Qty
2
Input W
89.5/81.5/77.5
Capacitor uF
2.5uF/450V
Speed(Hi/Mi/Lo) r/min
1170/1070/995
Indoor coil
Number of rows
3
Tube pitch(a)×row
pitch(b)
mm
25.4×22
Fin spacing mm
1.7
Fin type (code)
Hydrophilic aluminum
Tube outside dia.and type
mm
φ9.5 Inner grooved copper
tube
Coil length×height×width mm
1360×254×66
Number of circuits
5
Indoor air flow(Hi/Mi/Lo)
m
3
/h
2000/1800/1600
Indoor noise level (sound pressure) dB(A)
50/49/47
Indoor unit
Dimension (W×H×D) mm
1670×240×680
Packing (W×H×D) mm
1715x273x760
Net/Gross weight kg
46/56
Refrigerant type
R410A
Design pressure MPa
4.2/1.5
Refrigerant
piping
Liquid side/Gas side
mm
12.7/19
Drainage water pipe diameter mm
OD25
Controller
RG36C/BG(C)E
Operation temperature
17-30
Capacity Btu/h
65000
Input W
6835
COP
2.78