08 VS35W and VS35B Installer / User Manual
S2
S1
NSB
SL
L
N
S2
S1
NSB
SL
L
N
Sensor Terminal (optional)
Sensor Terminal (optional)
Night set back input
Load (Thermal Actuators)
Live 230V AC 50Hz
Neutral
LN
Wiring Centre
Thermal
Actuator
Optional SALUS
Sensor
Installation – Terminal Connections
L N
NSB from other
thermostats
Input
iT600 VS35W - VS35B Installer - User Manual 006_Layout 1 10.10.2014 12:00