3.5. FAULT MESSAGES & CLEARING FAULTS
If any fault occurs, the LCD screen will display the Fault Message and the Red LED “Fault” (4, Fig 1.1) will be lighted.
Refer to Table 7.1 at Section 7 for details of various fault messages and procedure to clear the fault.
CAUTION!
The cause of the fault should be removed before the unit is restarted.
ATTENTION!
La cause du défaut doit être éliminée avant le redémarrage de l'unité.
3.6 OPERATING MODES AND ASSOCIATED LCD DISPLAY SCREENS
3.6.1 General Information
When the unit is operating normally, the LCD Screen will display the name of the Operating Mode and values of various
associated operating parameters. As all the operating parameters associated with a particular Operating Mode cannot
be displayed in one screen, multiple screens are available that can be accessed by scrolling the Up and Down Keys.
For ease of navigating through the various screens, all the screens covering a particular Operating Mode have been
arranged in a Menu Map – for example, see Menu Map for Inverting Mode at Figs 3.2(a) and 3.2(b). Table 3.1 shows
the names of the Operating Modes and the Fig Nos. of the associated Menu Maps.
Typical Operating Mode Display Screen is shown in Fig 3.0 [Copy of Screen 1 of Inverting Mode Menu Map at Fig
3.2(a)]. There are 4 lines of display (up to 20 characters per line). The 1st line shows the Model No on the left side and
the Operating Mode on the right side. The 2nd, 3rd and the 4th lines display various operating parameters and their
values.
E V O - 1 2 1 2 F I n v e r t i n g
A C o u t p u t : 1 2 0 . 0 V
< 0 . 1
A
6 0 . 0 0 H
z
Fig 3.0 Typical Operating Mode Display Screen
[Screen No. 1 of Inverting Mode Menu Map at Fig 3.2(a)]