SAMLEX AMERICA INC. | 69
SECTION 4 | Parameter Setup
4.5.2.4 HIGH CUT OFF (Table 4.6: (i) Parameter Setup Screen No.3 for EVO-1212F/EVO-1212F-HW/EVO-1224F/EVO-1224F-HW
(ii) Parameter Setup Screen No.4 for EVO-2212/EVO-3012/EVO-2224/EVO-4024)
If the AC input frequency is over the value of “HIGH CUT OFF” when in "Charging Mode", the EVO™ Inverter/
Charger will transfer to Inverting Mode.
4.5.2.4.1 Programming Steps for Parameter "HIGH CUT OFF"
ð ð
E V O - 1 2 1 2 F I n v e r t i n g
A C o u t p u t : 1 2 0 . 0 V
< 0 . 1 0 A
6 0 . 0 0 H z
Enter Key
Any Operating Mode Screen from
Fig 3.1 to 3.5
[Above screen is Screen 1 of Fig 3.2(a)]
Password 8052
See Section 4.3.1
S e l e c t G r o u p
* C H A R G E C U R V E
ð
S e l e c t P a r a m e t e r
* I N P U T S E T T I N G
ð
S e l e c t P a r a m e t e r
I N P U T S E T T I N G
* D E F A U L T F R E Q
0 = 6 0 H z
S e l e c t P a r a m e t e r
I N P U T S E T T I N G
* H I G H C U T O F F
6 5 H z
Down Key x 1 time
Enter Key
P a s s w o r d k e y i n
0 0 0 0
ð
Enter Key
S e l e c t P a r a m e t e r
I N P U T S E T T I N G
* H I G H C U T O F F
6 5 H z
ð
Enter Key
4.5.2.5 HIGH RESET (Table 4.6: (i) Parameter Setup Screen No.4 for EVO-1212F/EVO-1212F-HW/EVO-1224F/EVO-1224F-HW
(ii) Parameter Setup Screen No.5 for EVO-2212/EVO-3012/EVO-2224/EVO-4024)
This is the reset frequency at which the unit will revert to "Charging Mode" after it has switched over to "Inverter
Mode" due to input frequency rising above "HIGH CUT OFF".
4.5.2.5.1 Programming Steps for Parameter "HIGH RESET"
ð ð
E V O - 1 2 1 2 F I n v e r t i n g
A C o u t p u t : 1 2 0 . 0 V
< 0 . 1 0 A
6 0 . 0 0 H z
Enter Key
Any Operating Mode Screen from
Fig 3.1 to 3.5
[Above screen is Screen 1 of Fig 3.2(a)]
Password 8052
See Section 4.3.1
S e l e c t G r o u p
* C H A R G E C U R V E
ð
S e l e c t P a r a m e t e r
* I N P U T S E T T I N G
ð
S e l e c t P a r a m e t e r
I N P U T S E T T I N G
* D E F A U L T F R E Q
0 = 6 0 H z
S e l e c t P a r a m e t e r
I N P U T S E T T I N G
* H I G H R E S E T
6 4 H z
Down Key x 1 time
Enter Key
P a s s w o r d k e y i n
0 0 0 0
ð
Enter Key
S e l e c t P a r a m e t e r
I N P U T S E T T I N G
* H I G H R E S E T
6 4 H z
ð
Enter Key
4.5.2.6 LOW CUT OFF (Table 4.6: (i) Parameter Setup Screen No.5 for EVO-1212F/EVO-1212F-HW/EVO-1224F/EVO-1224F-HW
(ii) Parameter Setup Screen No.6 for EVO-2212/EVO-3012/EVO-2224/EVO-4024)
If the AC input frequency is below “LOW CUT OFF” value when in "Charging Mode", the EVO™ Inverter/Charger will
transfer to Inverting Mode.
(i) Down Key x 2 times for EVO-
1212F/1212F-HW/1224F/1224F-HW
(ii) Down Key x 3 times for EVO-
2212/3012/2224/4024
(i) Down Key x 3 times for EVO-
1212F/1212F-HW/1224F/1224F-HW
(ii) Down Key x 4 times for EVO-
2212/3012/2224/4024
For programmable options, see Table 4.6:
(i) Parameter Setup Screen No. 3 for
EVO-1212F/EVO-1212F-HW/EVO-1224F/EVO-1224F-HW
(ii) Parameter Setup Screen No. 4 for
EVO-2212/EVO-3012/EVO-2224/EVO-4024
For programmable options, see Table 4.6:
(i) Parameter Setup Screen No. 4 for
EVO-1212F/EVO-1212F-HW/EVO-1224F/EVO-1224F-HW
(ii) Parameter Setup Screen No. 5 for
EVO-2212/EVO-3012/EVO-2224/EVO-4024