SAMLEX AMERICA INC. | 81
SECTION 4 | Parameter Setup
4.7.2 Description of Parameters Under Group 4 – INPUT HIGH LIMIT
4.7.2.1 RESET VOLTAGE (Table 4.8, Parameter Setup Screen No.1)
This is the reset voltage at which the unit will revert to "Charging Mode" after it has switched over to "Inverting Mode"
due to input AC voltage rising to "CUT-OFF VOLT 1/CUT-OFF VOLT 2/CUT-OFF VOLT 3.
4.7.2.1.1 Programming Steps for Parameter "RESET VOLTAGE"
ð ð
E V O - 1 2 1 2 F I n v e r t i n g
A C o u t p u t : 1 2 0 . 0 V
< 0 . 1 0 A
6 0 . 0 0 H z
Enter Key Enter Key
Any Operating Mode Screen from
Fig 3.1 to 3.5
[Above screen is Screen 1 of Fig 3.2(a)]
Password 8052
See Section 4.3.1
See Table 4.8, Parameter Setup
Screen No. 1
for programmable range
S e l e c t G r o u p
* C H A R G E C U R V E
ð
S e l e c t P a r a m e t e r
* I N P U T H I G H L I M I T
ð
S e l e c t P a r a m e t e r
I N P U T H I G H L I M I T
* R E S E T V O L T A G E
1 2 5 . 0 V
Down Key x 3 times
Enter Key
S e l e c t P a r a m e t e r
I N P U T H I G H L I M I T
* R E S E T V O L T A G E
1 2 5 . 0 V
P a s s w o r d k e y i n
0 0 0 0
ð
Enter Key
4.7.2.2 CUT OFF VOLT 1 (Table 4.8, Parameter Setup Screen No.2)
If during "Charging Mode", the AC input voltage rises above "CUT-OFF VOLT 1" for period > "DETECT TIME 1", the
EVO™ Inverter/Charger will transfer to "Inverting Mode".
4.7.2.2.1 Programming Steps for Parameter "CUT OFF VOLT 1"
ð ð
E V O - 1 2 1 2 F I n v e r t i n g
A C o u t p u t : 1 2 0 . 0 V
< 0 . 1 0 A
6 0 . 0 0 H z
Enter Key Down Key x 1 time
Any Operating Mode Screen from
Fig 3.1 to 3.5
[Above screen is Screen 1 of Fig 3.2(a)]
Password 8052
See Section 4.3.1
See Table 4.8, Parameter Setup
Screen No. 2
for programmable range
S e l e c t G r o u p
* C H A R G E C U R V E
ð
S e l e c t P a r a m e t e r
* I N P U T H I G H L I M I T
ð
S e l e c t P a r a m e t e r
I N P U T H I G H L I M I T
* R E S E T V O L T A G E
1 2 5 . 0 V
S e l e c t P a r a m e t e r
I N P U T H I G H L I M I T
* C U T O F F V O L T 1
1 3 5 . 0 V
Down Key x 3 times
Enter Key
P a s s w o r d k e y i n
0 0 0 0
ð
Enter Key
S e l e c t P a r a m e t e r
I N P U T H I G H L I M I T
* C U T O F F V O L T 1
1 3 5 . 0 V
ð
Enter Key
4.7.2.3 DETECT TIME 1 (Table 4.8, Parameter Setup Screen No.3)
This is the time limit in cycles up to which high AC input voltage "CUT-OFF VOLT 1"is allowed.
4.7.2.3.1 Programming Steps for Parameter "DETECT TIME 1"
ð ð
E V O - 1 2 1 2 F I n v e r t i n g
A C o u t p u t : 1 2 0 . 0 V
< 0 . 1 0 A
6 0 . 0 0 H z
Enter Key Down Key x 2 times
Any Operating Mode Screen from
Fig 3.1 to 3.5
[Above screen is Screen 1 of Fig 3.2(a)]
Password 8052
See Section 4.3.1
See Table 4.8, Parameter Setup
Screen No. 3
for programmable range
S e l e c t G r o u p
* C H A R G E C U R V E
ð
S e l e c t P a r a m e t e r
* I N P U T H I G H L I M I T
ð
S e l e c t P a r a m e t e r
I N P U T H I G H L I M I T
* R E S E T V O L T A G E
1 2 5 . 0 V
S e l e c t P a r a m e t e r
I N P U T H I G H L I M I T
* D E T E C T T I M E 1
6 0 c y c l e
Down Key x 3 times
Enter Key
P a s s w o r d k e y i n
0 0 0 0
ð
Enter Key
S e l e c t P a r a m e t e r
I N P U T H I G H L I M I T
* D E T E C T T I M E 1
6 0 c y c l e
ð
Enter Key