94 | SAMLEX AMERICA INC.
SECTION 4 | Parameter Setup
4.8.2.11.1 Programming Steps for Parameter "PARAMETER SAVE"
ð ð
E V O - 1 2 1 2 F I n v e r t i n g
A C o u t p u t : 1 2 0 . 0 V
< 0 . 1 0 A
6 0 . 0 0 H z
Enter Key
Any Operating Mode Screen from
Fig 3.1 to 3.5
[Above screen is Screen 1 of Fig 3.2(a)]
Password 8052
See Section 4.3.1
See Table 4.9
for programmable options
S e l e c t G r o u p
* C H A R G E C U R V E
ð
S e l e c t P a r a m e t e r
* O T H E R F U N C T I O N
ð
S e l e c t P a r a m e t e r
O T H E R F U N C T I O N
* P O W E R S A V I N G
0 = D i s a b l e
S e l e c t P a r a m e t e r
O T H E R F U N C T I O N
* B U Z Z E R
1 = O n
Down Key x 4 times
Enter Key
P a s s w o r d k e y i n
0 0 0 0
ð
Enter Key
S e l e c t P a r a m e t e r
O T H E R F U N C T I O N
* B U Z Z E R
1 = O n
ð
Enter Key
4.8.2.12 TEMP UNIT
(Table 4.9, (i) Parameter Setup Screen No. 11 under Column 1 (ii) Parameter Setup Screen No. 12 under Column 2)
Temperature display can be selected in °C or °F. Default is in °C.
4.8.2.12.1 Programming Steps for Parameter "TEMP UNIT"
ð ð
E V O - 1 2 1 2 F I n v e r t i n g
A C o u t p u t : 1 2 0 . 0 V
< 0 . 1 0 A
6 0 . 0 0 H z
Enter Key
Any Operating Mode Screen from
Fig 3.1 to 3.5
[Above screen is Screen 1 of Fig 3.2(a)]
Password 8052
See Section 4.3.1
See Table 4.9
for programmable options
S e l e c t G r o u p
* C H A R G E C U R V E
ð
S e l e c t P a r a m e t e r
* O T H E R F U N C T I O N
ð
S e l e c t P a r a m e t e r
O T H E R F U N C T I O N
* P O W E R S A V I N G
0 = D i s a b l e
S e l e c t P a r a m e t e r
O T H E R F U N C T I O N
* T E M P U N I T
0 = C
Down Key x 4 times
Enter Key
P a s s w o r d k e y i n
0 0 0 0
ð
Enter Key
S e l e c t P a r a m e t e r
O T H E R F U N C T I O N
* T E M P U N I T
0 = C
ð
Enter Key
4.8.2.13 PASSWORD DISABLE
(Table 4.9, (i) Parameter Setup Screen No. 12 under Column 1 (ii) Parameter Setup Screen No. 13 under Column 2)
In default condition, Password (8052) is required to change the value of programmable parameter. Use of Password
prevents accidental change of parameter setting.
4.8.2.13.1 Programming Steps for Parameter "PASSWORD DISABLE"
ð ð
E V O - 1 2 1 2 F I n v e r t i n g
A C o u t p u t : 1 2 0 . 0 V
< 0 . 1 0 A
6 0 . 0 0 H z
Enter Key
Any Operating Mode Screen from
Fig 3.1 to 3.5
[Above screen is Screen 1 of Fig 3.2(a)]
Password 8052
See Section 4.3.1
See Table 4.9
for programmable options
S e l e c t G r o u p
* C H A R G E C U R V E
ð
S e l e c t P a r a m e t e r
* O T H E R F U N C T I O N
ð
S e l e c t P a r a m e t e r
O T H E R F U N C T I O N
* P O W E R S A V I N G
0 = D i s a b l e
S e l e c t P a r a m e t e r
O T H E R F U N C T I O N
* P A S S W O R D D I S A B L E
0 = N o
Down Key x 4 times
Enter Key
P a s s w o r d k e y i n
0 0 0 0
ð
Enter Key
S e l e c t P a r a m e t e r
O T H E R F U N C T I O N
* P A S S W O R D D I S A B L E
0 = N o
ð
Enter Key
(i) Down Key x 9 times for EVO-
1212F/1212F-HW/1224F/1224F-HW
(ii) Down Key x 10 times for EVO-
2212/3012/2224/4024
(i) Down Key x 10 times for EVO-
1212F/1212F-HW/1224F/1224F-HW
(ii) Down Key x 11 times for EVO-
2212/3012/2224/4024
(i) Down Key x 11 times for EVO-
1212F/1212F-HW/1224F/1224F-HW
(ii) Down Key x 12 times for EVO-
2212/3012/2224/4024