40 EB 8546 EN
Rotatingsupplementarylter
8 Rotatingsupplementarylter
The rotating supplementary lter (Fig.14) is
designed for mounting to Type4708-53 and
Types4708-55 to -64 Supply Pressure
Regulators
1)
. It replaces the small integrated
lter cartridge. The entire lter housing can
be rotated by 360° to ensure that the
condensate drain always faces downwards.
Filter versions
Aluminum body with lter in transparent
plastic receptacle
Temperature range: –25 to +70°C,
order no. 1402-1132
Specialversion:
Temperature range: –50 to +70°C,
order no. 1402-1133
8.1 Mounting the rotating
supplementarylter
1. Remove the cover and lter cartridge
from the supply pressure regulator.
2. Place the supplied seal carefully onto the
groove (see arrow) of the connection.
3. Insert connecting pipe together with seal
into the supply pressure regulator and
tighten the plastic coupling nut.
Î Make sure that the seal does not fall out
of the groove on mounting.
4. Adjust the direction of the supplementary
lter until it is upright.
5. Secure the position by tightening the
hexagonal socket screw (6mm).
Fig.18:Connection and seal for supplementary
lter
9 Adjusting the set point
Î Refer to Fig.2
Î Unscrew the cap (5) on the set point
screw (7) and adjust the set point of the
supply pressure regulator.
Î Turning the screw clockwise increases the
output pressure and turning it counter-
clockwise reduces the output pressure.
Î Lock the setting with the lock nut (8).
Risk of damage to the supply pressure regu-
lator due to excessively high tightening
torque applied to the lock nut.
Do not exceed the maximum torque of
7Nm.
NOTICE
!
1)
Year of manufacture 2017 onwards