1. RLA is based on AHRI 210/240 colling standard condition [Indoor temp. : 26.7 °C / 80 °F(DB) / 19.46°C /
67°F(WB), Outdoor temp. : 35 °C / 95 °F(DB)]
2. Voltage tolerance is ± 10%.
3. Maximum allowable voltage between phases is 2%.
Symbols
t RLA : Rated Load Ampere
t FLA : Full Load Ampere
t MCA : Minimum Circuit Ampere (A)
t MOP : Maximum Overcurrent Protective Device (A)
NOTE
Between Indoor unit and Outdoor unit Connection Cable Specications(Common in use)
Power supply
Communication Cable
Power supply Max/Min(V)
Indoor Power Cable
1Φ, 208~230V, 60Hz ±10%
0.0039 in² , 3wires
0.0011~0.0023 in², 2wires
f Power supply cords of parts of appliances for outdoor use shall not be lighter than polychloroprene sheathed exible
cord. (Code designation IEC:60245 IEC 57 / CENELEC: H05RN-F or IEC:60245 IEC 66 / CENELEC: H07RN-F)
When installing the indoor unit in a computer room or net work room, use the
double shielded (Tape aluminum / polyester braid + copper ) cable of FROHH2R
type.
1-phase terminal block spec
AC power : M4 screw Communication : M4 screw
1(L) 2(N)
N
L
0.59 0.47
L1 L2 L1 L2
INDOOR POWER OUTDOOR POWER
10.1
11.4
Connecting the cable