30
Installation Procedure
English
Installation Procedure
Display contents SEG1 SEG2 SEG3 SEG4
K4 long
push
- Main micom version Year (Dec) Month (Hex) Date (Tens digit) Date (Units digit)
After short push 1 Inverter micom version Year (Dec) Month (Hex) Date (Tens digit) Date (Units digit)
After short push 2 E2P version Year (Dec) Month (Hex) Date (Tens digit) Date (Units digit)
After short push 3
Page 1 - AUTO
Page 2 - (SEG1,2 - Indoor : "A","0") (SEG3,4 - Address : ex) 00)
After short push 4
Page 1 - MANU
Page 2 - (SEG1,2 - Indoor : "A","0") (SEG3,4 - Address : ex) 00)
Long push K4 (Main micom ver.) → short push 1 more (Inv. micom ver.) → short push 1 more (E2P. ver.) → short push 1
more (Automatic address) → short push 1 more (Manual address) → short push 1 more (Main micom ver.) → ....... → Long
push K4 (View mode end)
7 Setting outdoor unit option switch and address manually
a Setting the option
Press and hold K2 to enter the option setting.
(Only available when the operation is stopped)
If you enter the option setting, display will show
the following.
Seg 1 and Seg 2 will display the number for
selected option.
Seg 3 and Seg 4 will display the number for set
value of the selected option.
If you have entered option setting, you can shortly
press the K1 switch to adjust the value of the Seg 1,
Seg 2 and select the desired option.
Example)
If you have selected desired option, you can shortly
press the K2 switch to adjust the value of the Seg 3,
Seg 4 and change the function for the selected option.
Example)
After selecting the function for options, press and
hold the K2 switch for 2 seconds. Edited value of
the option will be saved when entire segments
blinks and tracking mode begins.
Option
item
Input
unit
SEG1 SEG2 SEG3 SEG4 Function
Channel
address
Main 0 0
A U
Automatic
setting
(Factory
default)
00~15
Manual
setting
Snow
accumulation
prevention
control
Main 0 1
0 0
Disabled
(Factory
default)
0 1 Enabled
Step for
Silence mode
Main 0 2
0 0
Disabled
(Factory
default)
0 1 Step1
0 2 Step2
0 3 Step3
Type of
Silence mode
Main 0 3
0 0
Automatic
Silence mode
(Factory
default)
0 1
Manual
Silence mode
Temperature
unit
Main 0 4
0 0
Celsius
(default)
0 1 Fahrenheit
Not applicable Main 0 5
0 0 Not applicable
0 1 Not applicable
DB68-11274A-00_IM_CAC Universal Outdoor_AA_EN.indd 30DB68-11274A-00_IM_CAC Universal Outdoor_AA_EN.indd 30 2021-09-14 오전 9:22:012021-09-14 오전 9:22:01