Samsung Electronics 4-5
1. Check whether power is supplied or not.
- When the indoor unit is not plugged in, there should be additional power supply in the indoor unit.
2. The panel(display ) should be connected to an indoor unit to receive option.
3. Set the installation option according to the installation condition of an air conditioner.
- The default setting of an indoor unit installation option is “02000-100000-200000-300000”.
- Individual control of a remote controller(SEG20) is the function that controls an indoor unit individually when there is
more than one indoor unit.
- No need to assign SEG3, 6, 9, 10, 11, 16, 21, 22, 23, 24 which are non applicable. Even though those segments are set,
they will be ignored.
- If you set the applicable segments with numbers other than the indiciated, the initial setting will be maintained.
4. Set the indoor unit option by wireless remote controller.
4-1-3 Setting an indoor unit installation option (suitable for the condition of each installation location)
Option No. : 02XXXX-1XXXXX-2XXXXX-3XXXXX
Option
SEG1 SEG2 SEG3 SEG4 SEG5 SEG6
Explanation
PAGE MODE
RESERVED
Useofexternal
temperature sensor
Useofcentral
control
RPMsetting
compensation
Indication
and
Details
Indication
Details
Indication
Details
Indication
Details
Indication
Details
0. Not used
1. High ceiling mode
2. High ceiling kit
3. Low noise operation mode
0 2
0 Disuse 0 Disuse
1 Use 1 Use
Option
SEG7 SEG8 SEG9 SEG10 SEG11 SEG12
Explanation
PAGE Useofdrainpump
RESERVED RESERVED RESERVED
Master/Slave
Indication
and
Details
Indication
Details
Indication
Details
Indication
Details
1
0 Disuse 0 slave
1 Use 1 master
2
Use+
3minute
delay
Option
SEG13 SEG14 SEG15 SEG16 SEG17 SEG18
Explanation
PAGE
Useofexternal
control
Setting the output
ofexternalcontrol
S-Plasma ion Buzzer control
Numberofhours
using lter
Indication
and
Details
Indication
Details
Indication
Details
Indication
Details
Indication
Details
Indication
Details
Indication
Details
2
0 Disuse 0
Thermo
on
0
Disuse 0
Useofbuzzer
2
1000Hour
1
ON/OFF
Control
1
Operation
on
1
Use 1
Nonuse
of buzzer
6
2000
Hour
2
OFF
Control