EasyManua.ls Logo

Samsung AF28FVSDA N Series - External OLP Temperature Sensor Error

Samsung AF28FVSDA N Series
101 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Troubleshooting
Samsung Electronics 4-25
4-4-16 External OLP temperature sensor error
Indoor unit display
Outdoor unit display
(YEL)
(GRN)
(RED)
1. Cause of malfunction
1) Disconnection or loose connection of sensor wire
2) Faulty sensor itself
3) Problematic outdoor unit PBA
2. Check procedure
Pull out power cords for the indoor unit
and the outdoor unit
After detaching the ass’y control out
cover, detach the olp/cond connector
from the PBA
Yes
Measure resistance on both ends
of olp pin using a test device
Replace faulty or broken sensor itself
No
Is the resistance reading in the range of
220k~240k?
Yes
Replace outdoor unit PBA
(A new EEPROM IC must be inserted)
S Equipment claims must be made at a service center for the EEPROM IC.