Do you have a question about the Samsung AM BXVGFH/AA Series and is the answer not in the manual?
Details the version updates and release dates of the technical data book.
Details the meaning of each character in the outdoor unit model name.
Highlights the advanced features and benefits of the DVM S2 system.
Details the compressor technology and its performance advantages.
Lists outdoor unit models and their corresponding capacity combinations.
Shows the external appearance of outdoor units for 208-230V and 460V.
Defines Combination Ratio (CR) and illustrates the system design process.
Explains how to ensure comfort and provides examples of peak load calculations.
Details allowable CR limits and provides graphs relating CR to operation ratio.
Specifies indoor unit types that limit CR extension beyond 130%.
Covers basic specifications for smaller 208-230V outdoor units.
Details wiring, refrigerant, sound, dimensions, and temp range for 208-230V units.
Presents capacity data for AM144-192BXVGFH/AA models.
Presents capacity data for AM072-120BXVGJH/AA models (460V).
Details electrical characteristics for 208-230V Heat Pump/Recovery models.
Details electrical characteristics for 460V Heat Pump/Recovery models.
Shows dimensional drawings for AM072BXVGFH/AA and AM072BXVGJH/AA outdoor units.
Shows dimensional drawings for AM096-168BXVGFH/AA and AM096-168BXVGJH/AA outdoor units.
Shows dimensional drawings for AM192-240BXVGFH/AA and AM192-240BXVGJH/AA outdoor units.
Provides center of gravity dimensions for the AM072BXVG*H/AA model.
Provides center of gravity dimensions for AM096-168BXVG*H/AA models.
Provides center of gravity dimensions for AM192-240BXVG*H/AA models.
Shows the electrical wiring diagram for AM072BXVGFH/AA and AM072BXVGJH/AA outdoor units.
Shows the electrical wiring diagram for AM096-144BXVGFH/AA and AM096-144BXVGJH/AA outdoor units.
Shows the electrical wiring diagram for the AM168BXVGFH/AA outdoor unit.
Shows the electrical wiring diagram for the AM192BXVGJH/AA outdoor unit.
Shows wiring diagrams for AM192-240BXVGFH/AA and AM216-240BXVGJH/AA outdoor units.
Presents sound pressure levels and NC curves for AM072-240BXVGFH/AA models.
Presents sound pressure levels and NC curves for AM072-240BXVGJH/AA models.
Lists sound power levels and NC curves for AM072-240BXVGFH/AA models.
Lists sound power levels and NC curves for AM072-240BXVGJH/AA models.
Shows the continuous and expanded operational ranges for cooling and heating.
Details how defrost operation affects heating capacity and provides a correction factor.
Illustrates the refrigerant piping for AM072BXVGFH/AA and AM072BXVGJH/AA outdoor units.
Illustrates the refrigerant piping for AM096-168BXVGFH/AA and AM096-168BXVGJH/AA outdoor units.
Illustrates the refrigerant piping for AM192BXVGFH/AA and AM192BXVGJH/AA outdoor units.
Illustrates the refrigerant piping for AM216-240BXVGFH/AA and AM216-240BXVGJH/AA outdoor units.
Provides guidelines for selecting an outdoor unit installation location.
Details space requirements for single and module outdoor unit installations.
Lists required installation manuals and optional accessories for piping.
Details requirements for constructing a stable and properly drained base for outdoor units.
Illustrates base mount and anchor bolt positions for different unit types.
Explains how to construct drainage ditches and apply slopes for defrost water.
Details the process of connecting refrigerant pipes and precautions for welding.
Illustrates correct and incorrect methods for piping between outdoor units.
Shows examples of refrigerant pipe installation using Y-joints and distribution headers.
Provides allowable lengths for refrigerant pipes in various installation configurations.
Illustrates the process of connecting refrigerant pipes to the outdoor unit.
Details how to route power and communication cables using knock-out holes and protection tubes.
Illustrates power wiring configurations for different voltage and phase systems.
Details the process of connecting power cables to the terminal board and associated cautions.
Provides guidance on routing power cables and avoiding contact with pipes.
Details the steps for connecting ring terminals to 3-phase power cables.
Details the installation of the solution device for systems with up to 16 indoor units.
Presents AHRI performance data including capacity, EER, IEER, COP, and SCHE.