EasyManua.ls Logo

Samsung AM FNHDEH Series - Page 13

Samsung AM FNHDEH Series
44 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
13
ENGLISH
5. Check if you ared the pipe correctly. There are some examples of incorrectly ared pipes below.
InclinedCorrect Damaged Surface Cracked Uneven Thickness
6. Align the pipes and tighten the are nuts rst manually and then with
a torque wrench, applying the following torque.
Outer diameter
(D, mm)
Connection
Torque(N•m)
Flare dimension
(A, mm)
Flare shape
ø6.35 14~18 8.7~9.1
R 0.4~0.8
A
D
90° ±2°
45° ±2°
ø9.52 34~42 12.8~13.2
ø12.70 49~61 16.2~16.6
ø15.88 68~82 19.3~19.7
ø19.05 100~120 23.6~24.0
1N•m=10kgf•cm
In case of needing brazing, you must work with Nitrogen gas blowing.
CAUTION
NASA_Big Duct_AM@@@FNHDEH@_IM_03864A-05_EN.indd 13 2016-04-01 오후 5:29:41

Related product manuals