General IconGeneral
SeriesDVM S ECO AM XMDG Series
CategoryAir Conditioner
RefrigerantR410A
TypeVariable Refrigerant Flow (VRF)
Indoor Unit TypesCeiling Cassette, Wall Mount, Floor Standing
Control OptionsCentralized Control System
ConnectivityWireless (Optional)

Summary

Safety precautions for air conditioner installation

Preparations for Air Conditioner Installation

Base construction and outdoor unit installation

Air Conditioner Installation Procedures

Refrigerant pipe work guidelines

Guidelines for refrigerant pipe length, height difference, and bending.

Selecting the correct refrigerant pipe

How to select the correct refrigerant pipe size based on outdoor unit capacity.

Calculating and adding refrigerant

Information on calculating and adding refrigerant based on unit and pipe size.

Calculating total additional refrigerant amount

Provides formulas and examples for calculating total additional refrigerant.

Refrigerant pipe brazing safety

Important precautions and techniques for brazing refrigerant pipes safely.

Wiring work for air conditioner installation

Circuit breaker and power cable specifications

Details on circuit breaker capacity and power cable specifications for the outdoor unit.

Power wiring diagrams

Diagrams illustrating the power wiring connections for 3-phase and 1-phase systems.

Installing grounding wire correctly

Procedures for installing grounding wires based on power conditions and installation location.

Air tightness test and Vacuum drying procedures

Performing the air tightness test

Steps to perform an air tightness test using nitrogen gas at 4.1MPa.

Vacuum drying pipes and indoor units

Process for vacuum drying pipes and indoor units to remove moisture.

Charging refrigerant in the air conditioner

Refrigerant regulations and information

Regulations and precautions for handling fluorinated greenhouse gases like R-410A.

Pipe insulation for air conditioner components

Setting outdoor unit options and functions

Setting total indoor units via K1-K4

Guide to setting the total number of connected indoor units via buttons.

Post-installation checks

Inspection and test operation

Checklist before auto trial operation

A checklist of items to verify before performing auto trial operation.

Auto trial operation guide

Steps and considerations for conducting the auto trial operation.

Automatic refrigerant amount detection function