Troubleshooting
Samsung Electronics 303
Item Model
SEG
Static
Pressure
1 2 3 4 5 6 7 8 9 101112131415161718192021222324
EHS
TDM
PLUS
Slim Duct
AE022MNLDEH/EU
010954125E08201616321110
4mmAq
010954125AC3201616321110
2mmAq(STD)
010954125A80201616321110
0mmAq
AE028MNLDEH/EU
010954125E7A201C1C321110
4mmAq
010954125E15201C1C321110
2mmAq(STD)
010954125AE2201C1C321110
0mmAq
AE036MNLDEH/EU
010954125ECD202424321110
4mmAq
010954125E68202424321110
2mmAq(STD)
010954125E35202424321110
0mmAq
AE056MNLDEH/EU
010954125EF9203838321110
4mmAq
010954125E34203838321110
2mmAq(STD)
010954125AC1203838321110
0mmAq
EHS
TDM
PLUS
Global Duct
AE071MNMPEH/EU
0109541C59DF204747321201
12~15mmAq
0109541C5989204747321201
9~12mmAq
0109541C5935204747321201
6~9mmAq
0109541C55E1204747321201
3~6mmAq
0109541C548D204747321201
0~3mmAq(STD)
AE090MNMPEH/EU
0109541C59CD205A5A321212
12~15mmAq
0109541C5969205A5A321212
8~12mmAq
0109541C55E3205A5A321212
4~8mmAq
0109541C546D205A5A321212
0~4mmAq(STD)
A3050
(EEV
NOT
INCLUDED)
AE022MNADEH/EU
01294419942A201616320000
-
AE028MNADEH/EU
01294419945C201C1C320000
-
AE036MNADEH/EU
01294419845E202424320010
-
AE056MNADEH/EU
01294419942C203838320020
-
AE071MNLADEH/EU
01294419847F204747320020
-
Console
AE022MNJDEH/EU
019944195074201616320010
-
AE028MNJDEH/EU
0199441950B7201C1C320010
-
AE036MNJDEH/EU
0199441950D7202424320010
-
AE056MNJDEH/EU
01994419541B203838320010
-
Wind-Free 1way
Cassette
AM017NN1PEH/EU
01D044196086201111330000
-
AM022NN1PEH/EU
01D0441970A6201616330000
-
AM022NN1DEH/EU
0170441180C8201616330010
-
AM028NN1DEH/EU
0170441180F8201C1C330010
-
AM036NN1DEH/EU
01704411545D202424330011
-
AM056NN1DEH/EU
01804419543C203838330015
-
AM071NN1DEH/EU
01804419945F204747330018
-
4Way Cassette
(600x600)
AM028HNNDEH/TL
01605712595E201C1C330010
-
AM036HNNDEH/TL
01605712595E202424330010
-
AM045HNNDEH/TL
016057125AB3202D2D330010
-
7 If you are going to use up to SEG 24, please refer to following instruction.
SEG 17 : 0 £ 1: Using high ceiling kit for 4way
SEG 18 :
y If you want to use multiple functions, add each of the 'use' value of the function you want to used and input the final addition as option
value. (Use Fahrenheit + Sound mute + Mixed operation control : 1 + 2 + 4 = 7)
Ex) 044217-1d00e6-200000-300000
When using Sound mute : 044217-1d00e6-200002-300000
When using high ceiling kit for 4way and mixed operation error preventing function : 044217-1d00e6-200014-300000
Not in use Use
Change temperature display 0(Celsius) 1(Fahrenheit)
Sound Mute 0 2
Mixed operation control 0 4
Option Items(cont.)

Table of Contents