Troubleshooting
4-12 Samsung Electronics
Ŷ 02 series installation option(Detailed)
Option No. : 02XXXX-1XXXXX-2XXXXX-3XXXXX
Option SEG1 SEG2 SEG3 SEG4 SEG5 SEG6
Explanation PAGE MODE
Evaporator
Drying
Use of external room temperature
sensor / Minimizing fan operation when
thermostat is off
U
se of central
control
FAN RPM
compensation
Indication
and Details
I
ndication Details Indication Details Indication Details Indication
Details
Indication Details Indication Details
Use of External
room
temperature
sensor
M
inimizing fan
operation when
thermostat is off
02
0 Disuse
0 Default Default
0 Disuse 0 Disuse
1 Use Disuse
2 Disuse Use (Heating) (*2)
2
Use
(5min)
(*1)
3 Use Use (Heating) (*2)
4 Disuse Use (Cooling) (*2)
5 Use Use (Cooling) (*2)
4
Use
(10min)
(*1)
6 Disuse
Use (Heating /
Cooling) (*2)
1Use 1
RPM
compen-
sation
7Us
e
Use (Heating /
Cooling) (*2)
8 Disuse
Use (Cooling Ultra
Low Fan ) (*2)
6
Use
(30min)
(*1)
9Use
Use (Cooling Ultra
Low Fan ) (*2)
A Disuse
Use (Heating /
Cooling Ultra Low
Fan ) (*2)
BUse
Use (Heating /
Cooling Ultra Low
Fan ) (*2)
Option SEG13 SEG14 SEG15 SEG16 SEG17 SEG18
Explanation PAGE
Use of external
control
Setting the output of external control
/ External heater signal / Cooling operation
signal / F
ree Cooling control signal
Buzzer control
Hours of filter
usage
Indication
and Details
Indication Details Indication Details Indication Details Indication Details Indication Details
2
0 Disuse 0 External control (Thermo On)
0 Use buzzer 2
1000
Hour
1
ON/OFF
control
1 External control (Operation On)
2 External heater signal (*4)
2
"OFF
control"
3 External heater signal (*4)
1
Disuse
buzzer
6
2000
Hour
4 Cooling operation signal (*5)
3
Window
ON/OFF
control
5
Free Cooling control
(Cooling Thermo On) (*6)
6
Free Cooling control
(Cooling/Dry Thermo On) (*6)
Option SEG19 SEG20 SEG21 SEG22 SEG23 SEG24
Explanation PAGE
Individual control of a
remote controller
H
eating setting
compensation
Adjusted EEV step of
stopped unit during oil
return /defrost mode.
Indication
and Details
Indication Details Indication Details Indication Details Indication Details
3
0 or 1 channel 1 0 Default 0 Default
2 channel 2 1 2 °C
1 Adjusted EEV positon 3 channel 3
25 °C
4 channel 4