EasyManua.ls Logo

Samsung AM048KN4DCH/AA - User Manual

Samsung AM048KN4DCH/AA
404 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
SYSTEM AIRCONDITIONER CONTENTS
SYSTEM AIRCONDITIONER
INDOOR UNIT
AM007/009/012FN1DCH/AA
AM009/012/018/020FNNDCH/AA
AM009/012/018/024/030/036/048FN4DCH/AA
AM007/009/012FNLDCH/AA
AM018/024FNLDCH/AA
AM030/036/048FNLDCH/AA
AM018/024FNMDCH/AA
AM030/036FNMDCH/AA
AM048FNMDCH/AA
AM007/009/012/018/020/024FNTDCH/AA
AM007/009/012/018/020/024HNQDCH/AA
AM036/048FNHDCH/AA
AM076/096FNHDCH/AA
AM018/024FNCDCH/AA
AM048/096HNPDCH/AZ
AM007/009/012/015/018JNMDCH/AA
AM024/027/030/036/048JNHDCH/AA
AM036/048JNCDCH/AA
AM006/009/012/018/024JNFDCH/AA
AM006/009/012/018/024JNGDCH/AA
AM072/096JNESCH/AA
AM054KNMDCH/AZ
AM007/009/012/018/020/024KNQDCH/AZ
AM007/009/012/018/020/024KNTDCH/AZ
AM005/007/009/012/015/018/024/028MNVDCH/AA
AM007/009/012NN1DCH/AA
AM009/012/018/024/030/036/048KN4DCH/AA
AM007MNMDCH/AA
AM009MNMDCH/AA
AM012MNMDCH/AA
AM015MNMDCH/AA
AM018MNMDCH/AA
AM024MNMDCH/AA
AM027MNMDCH/AA
AM030MNMDCH/AA
AM036MNMDCH/AA
AM048MNMDCH/AA
AM032MNQDCH/AA
AM007NN1DCH/AZ
AM009NN1DCH/AZ
AM012NN1DCH/AZ
AM018NN1DCH/AZ
AM024NN1DCH/AZ
1. Precautions
2. Product Specifications
3. Disassembly and Reassembly
4. Troubleshooting
5. PCB Diagram and Parts List
6. Wiring Diagram
7. Reference Sheet

Table of Contents

Questions and Answers

  • K
    Kara Rogers MDJul 26, 2025
    Why does my Samsung Air Conditioner show a communication error between indoor and outdoor units?
    • J
      john09Jul 26, 2025
      This error occurs due to several reasons: 1. There is no communication between the indoor and outdoor units for 2 minutes. 2. A communication error was received from the outdoor unit. 3. There is a 3-minute tracking error on the outdoor unit. 4. A communication error occurred after tracking due to an unmatching number of installed units. 5. An error is due to a repeated communication address. 6. The communication address is not confirmed, or another outdoor unit communication error not listed above occurred. The error codes associated with these issues are E101, E102, E202, E201, E108 and E109.
  • C
    Courtney CampbellAug 2, 2025
    What does it mean when my Samsung Air Conditioner shows an error related to the outdoor temperature sensor?
    • C
      Christine CamachoAug 2, 2025
      An error related to the outdoor temperature sensor on your Samsung Air Conditioner could indicate: 1. Error on outdoor temperature sensor (Short or Open). 2. Error on cond sensor. 3. Error on discharge sensor. The error codes associated with these issues are E221, E237 and E251.
  • S
    smithjohnAug 9, 2025
    What does E121 error mean on a Samsung AM048KN4DCH/AA?
    • E
      Erik SolomonAug 9, 2025
      Error E121 on a Samsung Air Conditioner indicates an error on the indoor temperature sensor (Short or Open).
  • A
    antonio98Aug 17, 2025
    How to fix E108 error on Samsung AM048KN4DCH/AA?
    • P
      Peter CarpenterAug 17, 2025
      To fix the E108 error on your Samsung Air Conditioner, change the address and reset the system.

Summary

1. Precautions

1-1 Precautions for the Service

Guidelines for performing service on the air conditioner.

1-3 Precautions for the Safety

General safety guidelines to prevent electrical hazards.

3. Disassembly and Reassembly

3-1 Indoor Unit

Procedures for disassembling and reassembling indoor units.

4. Troubleshooting

4-1 Check-up Window Description

Explains the check-up window and its functions on the PCB.

4-2 Service Operation

Details special operations for service personnel.

4-3 Troubleshooting

General troubleshooting procedures and error code explanations.

4-3-3 What to check before diagnosis

Steps to diagnose problems before attempting repairs.

Diagnosis and Adjustment (Error Code)

Lists and explains various error codes for indoor units.

4-4 Appropriate Measures for Different Symptom

Provides measures for various symptoms and operational issues.

4-4-2 Main PCB has no power phenomenon

Troubleshooting steps for when the main PCB has no power.

4-4-3 Indoor Unit ROOM sensor Error (Open;Short)

Diagnosing and resolving errors related to the indoor room temperature sensor.

4-4-4 Indoor unit EVAP IN sensor Error (Open;Short)

Troubleshooting steps for EVAP IN sensor errors.

4-4-5 Indoor EVAP OUT sensor Error (Open;Short)

Diagnosing and resolving EVAP OUT sensor errors.

4-4-6 Indoor Heat Exchangers EVAP IN sensor dislocation error

Steps to diagnose EVAP IN sensor dislocation in the heat exchanger.

4-4-7 Indoor Heat Exchangers EVA OUT sensor dislocation error (Open;Short)

Troubleshooting steps for EVA OUT sensor dislocation in the heat exchanger.

4-4-9 Electronic Expansion Valve opening malfunction (2 nd stage) - E 135

Troubleshooting for EEV opening malfunction in the second stage.

4-4-10 Breakdown of EEV (2 nd)

Steps to diagnose and resolve EEV breakdowns.

4-4-11 Problem with EEV closure (2 nd)

Troubleshooting steps for EEV closure problems.

4-4-12: Detection of Floating Switch of Indoor Units Drain Pump

Diagnosing errors related to the indoor unit's drain pump floating switch.

4-4-13 The operational error of Indoor Units Fan Motor

Troubleshooting steps for indoor unit fan motor operational errors.

4-4-15 EEPROM error

Troubleshooting steps for EEPROM errors.

4-4-18 Simultaneous opening of Cooling;heating MCU SOL Valves 1 st;2 nd

Troubleshooting simultaneous MCU SOL valve errors.

4-4-19 Error due to incorrect Indoor Unit Power;Communication Cable Connection

Steps to fix errors from incorrect power or communication cable connections.

4-4-20 SPI Feedback Error

Diagnosing and resolving SPI feedback errors.

4-4-22 Communication Error between Indoor and Outdoor Units during Tracking

Troubleshooting communication errors during unit tracking.

4-4-23 Communication Error between Indoor and Outdoor Units after Tracking

Diagnosing communication errors after unit tracking is complete.

4-4-24 Communication error between main and sub Unit of outdoor unit or between outdoor units

Troubleshooting communication errors between outdoor unit components.

4-4-25 Communication Error between MCU and Outdoor Unit

Steps to resolve communication errors between MCU and outdoor unit.

4-4-26 Internal Communication error of the Outdoor Unit C-Box

Diagnosing internal communication errors within the outdoor unit C-Box.

4-4-27 Internal PCB Communication error of the Outdoor Unit C-Box

Troubleshooting internal PCB communication errors in the outdoor unit C-Box.

4-4-28 Communication Error between MCU and Outdoor Unit after Tracking is Completed

Resolving communication errors after MCU and outdoor unit tracking.

4-4-29 MCU branch part setup error - inconsecutive connection with the use of 2 branch parts

Diagnosing MCU branch setup errors due to non-consecutive connections.

4-4-30 MCU branch part setup error - Repeated setup for the same address over 3 times

Troubleshooting repeated MCU branch setup for the same address.

4-4-31 MCU branch part setup error - non-installed address setup

Diagnosing MCU branch setup errors for non-installed addresses.

4-4-37 Outdoor Temperature Sensor Error

Diagnosing and resolving outdoor temperature sensor errors.

4-4-39 Cond Out Temperature Sensor Error (Open;Short)

Diagnosing open/short errors for the Cond Out temperature sensor.

4-4-41 Digital Compressor Discharge Temperature Sensor Error (OPEN;SHORT)

Diagnosing open/short errors for the digital compressor discharge temperature sensor.

4-4-42 Constant Rate Compressor Discharge Temperature Sensor Error (OPEN;SHORT)

Troubleshooting open/short errors for the constant rate compressor discharge temperature sensor.

4-4-43 Compressor Discharge or Top 1;2 Temperature sensor error

Diagnosing errors for compressor discharge or top temperature sensors.

4-4-45: Suction Temperature sensor breakaway error

Diagnosing and resolving suction temperature sensor breakaway errors.

4-4-46 SUMP Temperature Sensor Error (OPEN;SHORT)

Troubleshooting open/short errors for the sump temperature sensor.

4-4-47 High Pressure sensor error (Open;Short)

Diagnosing open/short errors for the high pressure sensor.

4-4-48 Low Pressure sensor error (Open;Short)

Troubleshooting open/short errors for the low pressure sensor.

4-4-49 Suction Temperature sensor error (Open;Short)

Diagnosing open/short errors for the suction temperature sensor.

4-4-50 Liquid Pipe Temperature sensor error (Open;Short)

Troubleshooting open/short errors for the liquid pipe temperature sensor.

4-4-51 EVI In Temperature sensor error (Open;Short)

Diagnosing open/short errors for the EVI In temperature sensor.

4-4-52 EVI Out Temperature sensor error (Open;Short)

Troubleshooting open/short errors for the EVI Out temperature sensor.

4-4-53 Suction-2 Temperature Sensor Error (OPEN;SHORT)

Diagnosing open/short errors for the suction-2 temperature sensor.

4-4-54: Comp. Down due to High Pressure Protection Control

Troubleshooting compressor shutdown due to high pressure protection.

4-4-55: Comp. Down due to Low Pressure Protection Control

Diagnosing compressor shutdown due to low pressure protection.

4-4-57: Comp. Down due to Compressor Discharge Temperature sensor

Diagnosing compressor shutdown due to discharge temperature sensor issues.

4-4-59: Comp. Down by Compression Ratio Control

Diagnosing compressor down issues related to compression ratio control.

4-4-60 EVI EEV Open error

Troubleshooting steps for EVI EEV open errors.

4-4-61 Refrigerant Leakage Error

Diagnosing and resolving refrigerant leakage errors.

4-4-73: Compressor Excess Current Error

Troubleshooting compressor excess current errors.

4-4-78 Liquid Compression Prevention Control

Diagnosing and resolving liquid compression prevention control issues.

4-4-85 Breakdown of an EEV(1 st)

Troubleshooting EEV breakdown issues.

4-4-86 Breakdown of an EEV closure

Diagnosing and resolving EEV closure breakdowns.

4-4-87 Electronic expansion valve closing malfunction (2 nd stage)

Troubleshooting EEV closing malfunctions in the second stage.

4-4-88 Electronic expansion valve opening malfunction (2 nd stage)

Diagnosing EEV opening malfunctions in the second stage.

Samsung AM048KN4DCH/AA Specifications

General IconGeneral
BrandSamsung
ModelAM048KN4DCH/AA
CategoryAir Conditioner
LanguageEnglish