Home
Samsung
Air Conditioner
AM048NXMDCR
Samsung AM048NXMDCR User Manual
5
of 1
of 1 rating
92 pages
Give review
Manual
Specs
To Next Page
To Next Page
Loading...
Refer to the service manual in the GSPN(see the rear c
ov
er) for the more inf
ormation.
AIR CONDITIONER
C
ONTENTS
SY
STEM AIR
C
ONDITIONER
OUTDOOR UNIT
AM036NXMDCR
AM048NXMDCR
AM053NXMDCR
AM060NXMDCR
■
Pr
oduct Specific
ations
■
Disassembly and Reassembly
■
Refrigeran
t pipe installation
■
T
roubleshooting
■
PCB Diagram
■
W
iring Diagr
am
■
Refer
ence Sheet
■
Check Operation & Amoun
t of
Refregent A
utomatically Checking
2
Table of Contents
Default Chapter
2
Table of Contents
2
Product Specifications
4
The Feature of Product
4
Feature
4
Product Specifications
10
Disassembly and Reassembly
12
Refrigerant Pipe Installation
32
Examples of the Correct Refrigerant Pipe Installation for Heat Recovery
32
Examples of the Incorrect Refrigerant Pipe Installation for Heat Recovery
33
Troubleshooting
34
Error Display
34
Error Code
35
How to Take Measures for each Symptom
38
Communication Error between Indoor and Outdoor Units During Tracking (Error Code : E201)
38
Communication Error between Indoor and Outdoor Units after Completing Tracking (Error Code : E202)
39
Communication Error (1 Minute) between Main and Sub Micoms of an Outdoor Unit or Among Outdoor Units (Error Code : E203)
40
MCU Branch Part Setup Error - Inconsecutive Connection with the Use of 2 Branch Parts
41
MCU Branch Part Setup Error - Repeated Setup for the same Address over 3 Times
42
MCU Branch Part Setup Error - Non-Installed Address Setup
43
Communication Error (1 Minute) between Main and Sub Micoms of an Outdoor Unit or Among Outdoor Units (Error Code : E203)
44
MCU Branch Part Setup Error - Overlapping Indoor Unit Address Setup
45
MCU Branch Part Setup Error - Set as Being Used Without Connection to an Indoor Unit
46
MCU Branch Part Setup Error - Connect an Indoor Unit to a Branch Part Not Being Used
47
MCU Branch Part Setup Error - Connect more Indoor Units than What Is Actually Set up in MCU
48
MCU/MCU Subcooler Entrance/Exit Sensor Error (Open/Short)
49
Outdoor Temperature Sensor Error(Open/Short) (Error Code : E221, E231, E251, E269, E276, E311 E321, E322, E323)
50
High Pressure Temperature Sensor Error (Open/Short) (Error Code : E291) Low Pressure Temperature Sensor Error (Open/Short) (Error Code : E296)
51
Compressor down by Antifreeze Control (Error Code: E403)
52
Comp. down Due to a Protective Control of High Pressure (Error Code : E407)
53
Comp. down Due to a Protective Control of Low Pressure (Error Code : E410)
54
Comp. down Due to a Discharge Temperature Sensor of a Compressor (Error Code : E416)
55
Reverse Phase Detection Error (3Phase Outdoor Unit) (Error Code : E425)
56
ESC EEV Open Error (Error Code : E438)
57
Refrigerant Leakage Error (Error Code : E439)
58
Prohibition of the Compressor Operation Due to Outdoor Temperature (Error Code : E440, 441)
59
Refrigerant Leakage Error (During Operation) (Error Code : E443)
59
Outdoor Unit Fan Error (Error Code : E458, 475 )
60
Comp down Due to OLP Temperature Control (Error Code : E463)
61
Compressor Starting/Rotation Error (Error Code : E461, E467)
62
Current Error / PFC Overload Error (Error Code : E462, E484)
64
IPM over Current Error (Error Code : E464)
65
DC-Link Voltage Under/Over Error (Error Code : E466)
68
Others
70
PCB Diagram
71
Outdoor Unit PCB
71
Wiring Diagram
75
Phase (AM036/048/053/060NXMDCR)
75
Reference Sheet
76
Refrigerant Cycle Diagram
76
Am036/048/053Nxmdcr
76
AM036/048/053NXMDCR (Cooling Mode)
77
AM036/048/053NXMDCR (Main Cooling Mode)
78
AM036/048/053NXMDCR (Heating Mode)
79
AM036/048/053NXMDCR (Main Heating Mode)
80
Nomenclatures
81
Outdoor Unit
81
Check Operation & Amount of Refrigerant Automatically Checking
82
Check Operation
82
How to Troubleshoot of the "Undetermined
84
Automatic Commissioning Error Code
90
Automatic Refrigerant Amount Detection Function (Checking Th Amount of Refrigerant)
91
5
Based on 1 rating
Ask a question
Give review
Questions and Answers:
Need help?
Do you have a question about the Samsung AM048NXMDCR and is the answer not in the manual?
Ask a question
Samsung AM048NXMDCR Specifications
General
Cooling Capacity
48000 BTU/h
Refrigerant
R410A
Power Supply
220-240V, 50Hz
Operating Temperature (Cooling)
18°C to 43°C
Noise Level (Indoor)
45 dB(A)
Related product manuals
Samsung AM048NN4DCH Series
156 pages
Samsung AM048FXMDCH
101 pages
Samsung AM048TXMDCH
76 pages
Samsung AM048FNHDCH/AA
404 pages
Samsung AM048JNCDCH/AA
404 pages
Samsung AM048KN4DCH/AA
404 pages
Samsung AM040FXMDEH
79 pages
Samsung AM045TNVDKH
26 pages
Samsung AM045KNQDEH/TL
552 pages
Samsung AM045FNNDEH/EU
31 pages
Samsung AM040KXMDEH/EU
69 pages
Samsung AM045NN4DEH Series
156 pages