Specifies components and features of the indoor unit.
Guidelines for servicing the product, including part selection and connections.
General safety rules to follow during operation and repair to prevent hazards.
Environmental and safety precautions for handling refrigerant.
Guidelines for safely welding air conditioner pipes, including removing flammable materials.
Precautions for accurately calculating and supplementing refrigerant to avoid product damage.
Detailed technical specifications for various indoor unit models, including electrical, performance, and dimensions.
Step-by-step instructions for disassembling and reassembling indoor unit components.
Details special operational modes for service, including refrigerant charging and vacuum operations.
Provides methods to diagnose and resolve various error codes and symptoms.
Provides troubleshooting steps and solutions for various symptoms encountered with the units.
Steps to diagnose inverter overcurrent errors, checking installation, compressor, and PCB.
Troubleshooting over/low voltage errors, checking wiring and fuses.
Diagnosing DC link voltage sensor errors, checking power and reactor connections.
Troubleshooting liquid compression prevention control, checking sensors, EEV, and pipes.
How to diagnose EEV breakdown, checking connections and resistance.
Troubleshooting EEV closing malfunctions, checking wire connections and coil.
Steps to diagnose EEV opening malfunctions, checking connections, coil, and address settings.
Troubleshooting Hydro Unit water in temperature sensor errors, checking connectors and resistance.
Diagnosing Hydro Unit water out temperature sensor errors, checking connectors and resistance.
Steps to troubleshoot Hydro Unit water tank temperature sensor errors, checking connectors and resistance.
Diagnosing emergency errors related to water piping equipment, checking flow and temperatures.
Troubleshooting errors to prevent freezing and bursting of the heat exchanger.
Diagnosing breakaway errors of the water out temperature sensor, checking mounting and resistance.
Troubleshooting breakaway errors of the flow switch, checking connections and water flow.
Troubleshooting DC fan motor feedback errors, checking connectors and PCB.
Diagrams and parts lists for various indoor unit types, including PCB layouts.
Diagram and parts list for the Indoor Unit Power PCB.
Diagram and parts list for the Display PCB.
Wiring diagrams for various indoor unit types, detailing connections and components.
Instructions and precautions for performing pump-down operations on outdoor units.
Safety precautions to be taken before, during, and after refrigerant pump-down.
Procedure for pump-down when only one outdoor unit is installed.
Procedure for pump-down when two or more outdoor units are installed.
| Model | AM090FNLDEH/EU |
|---|---|
| Cooling Capacity | 9.0 kW |
| Heating Capacity | 10.0 kW |
| Power Supply | 380-415V, 50Hz |
| Refrigerant | R410A |












Loading...