Samsung Electronics 4-23
4-3-19 Operation condition secession error When is displayed
1. Checklist :
1)Check the temperature around the outdoor unit.
2.Troubleshooting procedure
Terminate the service
No
Is the operation condition secession error
appeared again?
Restart after power o
Yes
The temperature condition is too poor to operate.
Wait until temperature is changed.
**Heat Mode
Is the outdoor unit’s temperature over 40˚C or
under -30˚C?
**Cool Mode
Is the outdoor unit’s temperature under -7˚C?
Yes
4-3-20 capacity miss match error When is displayed
1. Checklist :
1)Check the Btu between indoor unit and outdoor unit
2) Check the indoor unit’s option code and outdoor unit’s EEPROM data.
2.Troubleshooting procedure
Exchange the one of them according to the exact
model spec
No
Is the the rated Btu between indoor unit and
outdoor unit
Exchange the outdoor unit’s PBA
Yes
Re-set the option code again at indoor unit
Terminate the service
No
Is the capacity miss match error appeared
again?
Yes