EasyManua.ls Logo

Samsung AR 24 RXFPEWQX - Indoor Unit Disassembly Procedures

Samsung AR 24 RXFPEWQX
112 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
19
4-1. Indoor Unit
NO. Parts Procedure Remark
1 PANEL-FRONT
1) Stop the driving of air conditioner
and shut off main power supply.
2) Open the FRONT-GRILLE and pull
out from the PANEL-FRONT.
3) Detach COVER-TERMINAL from
the PANELFRONT.(use + Screw
Driver)
4) Loosen connector wire(white) and
detach the temperature sensor wire.
5) To detach the FRONT-PANEL the
main frame, unfasten 2 screw at the
bottom.(use + Screw Driver)
6) Take off the FRONT-
PANEL,lifting up the bottom.

Table of Contents

Related product manuals