85
10-2-7 Operation condition secession error
Indoor display
3-LED DISPLAY
7-SEG DISPLAY DESCRIPTION
LED1 LED2 LED3
E440
Prohibit Operation Condition Error (Heating)
E441
Prohibit Operation Condition Error (Cooling)
Outdoor display
Operation condition secession
LED ON
LED BLINKING
LED OFF
1. Checklist :
1) Check the temperature around the outdoor unit.
2. Troubleshooting procedure
NO
YES
YES
Restart after power off
Terminate the service
Is the operation condition secession
error appeared again?
*Heatingmode*
Is the outdoor temperature over 40
or
under -30 ?
*Coolingmode*
Is the outdoor temperature under -7
?
The temperature condition is too poor to
operate. Wait until temperature is changed