35English
Installation
Optional accessories
Insulated assembly pipe,
Ø1/4inch (Ø6.35mm) (1)
Insulated assembly pipe,
Ø3/8inch(9.52mm) (1)
7709/1277
Insulated assembly pipe,
Ø1/2inch(12.70mm) (1)
771877
Insulated assembly pipe,
Ø5/8inch(15.88mm) (1)
772477
Drain Hose, 2 m long (1) Foam Insulation(1)
Pipe clamp A (3) Pipe clamp B (3)
Vinyl tape (2)
PE T3 foam tube
insulation (1)
Putty 100 g (1) Drain plug (1)
M4 x 25 tapped screw (6) Cement nail (6)
3-wire power cable (1)
2-wire assembly cable
(1)
3-wire assembly cable
(1)
Wired remote controller
(1)
Sub COMM PBA
Accessories in the outdoor unit package
Rubber leg (4)
NOTE
ŷ A flare nut is attached to the end of each pipe of an
evaporator or a service port. Use flare nuts when
connecting the pipes.
ŷ Wire assembly cables are optional. If they are not
supplied, use standard cables.
ŷ The drain plug and the rubber legs are included only
when the air conditioner is supplied without assembly
pipes.
ŷ If these accessories are supplied, they are in the
accessory package or outdoor unit package.
ŷ Wired remote controller is optional. It has no Filter
Reset function in this model.
ŷ At cool mode, when wireless Remote controller temp
setting is from 61oF~64oF, wired Remote controller
FDQGLVSOD\WKHVHWWLQJWHPSFRUUHFWO\EXWFDQŰWVHW
TEMP below from 64oF to 61oF .
Tools
General tools
ŷ Vacuum pump
(Backward flowing
prevention)
ŷ Manifold gauge
ŷ Stud finder
ŷ Torque wrench
ŷ Pipe cutter
ŷ Reamer
ŷ Pipe bender
ŷ Spirit level
ŷ Screwdriver
ŷ Spanner
ŷ Drill
ŷ L-wrench
ŷ Measuring tape
Tools for test operation
ŷ Thermometer
ŷ Resistance meter
ŷ Electroscope
Step 1.3 Drilling a hole through the
wall
Before fixing the installation plate to a wall and then
fixing the indoor unit to the installation plate, a window
frame, or a gypsum board, you must determine the
position of a hole (with 2.56 inch(65 mm) inner diameter)
through which the pipe bundle (consisting of power and
communication cables, refrigerant pipes, and drain hose)
will pass and then drill that hole.
1. Determine the position of a
2.56 inch(65 mm)
mm hole in consideration of the possible
directions of the pipe bundle and the
minimum distances between the hole and
the installation plate.