18
Indoor Unit Installation
English
Installation
3 Insert both sides of core wire of the power cable into the
connection sleeve.
Method 1: Push the core wire into the sleeve from
both sides.
Method 2: Twist the wire cores together and push it
into the sleeve.
Method 1 Method 2
Connection sleeve
Connection sleeve
4 Using a crimping tool, compress the two points and flip
it over and compress another two points in the same
location.
The compression dimension should be 8.0.
Compression
dimension
After compressing it, pull both sides of the wire to
make sure it is firmly pressed.
Compress it 4 times
5 mm
Method 1 Method 2
Compress it 4 times
5 mm
5 Wrap it with the insulation tape twice or more and
position your contraction tube in the middle of the
insulation tape.
40 mm
Insulation tape
Method 1
35 mm
Insulation tape
Method 2
6 Apply heat to the contraction tube to contract it.
Contraction tube
Method 1
Contraction tube
Method 2
7 After tube contraction work is completed, wrap it with the
insulation tape to finish.
Three or more layers of insulation are required.
Insulation tape
Method 1
Insulation tape
Method 2
CAUTION
Make sure that the connection parts are not exposed
to outside.
Be sure to use insulation tape and a contraction tube
made of approved reinforced insulating materials
that have the same level of withstand voltage with
the power cable. (Comply with the local regulations on
extensions.)
WARNING
In case of extending the electric wire, please DO NOT use
a round-shaped Pressing socket.
Incomplete wire connections can cause electric
shock or a fire.