44
NO. Parts Procedure
Remark
4
ASSY CABINET
SIDE RH
1) Unscrew and remove 11 screws on
Cabinet-sideRH.(Use+Screw
Driver)
5
ASSY CABINET
FRONT
1) Unscrew and remove 7 screws on
AssyCabinetFront.(Use+Screw
Driver)
6 ASSY CONTROL
OUT
1) Disconnect and Separate 5 Con-
nectors of wire from Assy Control
Out.
2) Separate Comp wire from each
object.
Caution:
(When you disconnect
BLDC motor connector you have to
cutthepoweroffrstanddiscon-
nect 30 seconds later And Make sure
that is impossible to connect and
disconnect BLDC motor connector
when the power is on)
3) Unscrew and remove 2 screws on
of Assy Control out.