No. Parts Procedure Remark
5 Capillary 1) Please remove the weld point in one
place. (COND-OUT)
If you remove the compressor and
heat exchanger, eliminate the refrigerant
inside the compressor and heat
exchanger completely with welding re
to remove the PIPE.
2) Please separate NUT SERVICEVALVE
2EA. (MONKEY SPANNER or + SCREW
DRIVER Use).
6 Condenser
(heat exchanger)
1) Please remove the welds in one place.
(COND-IN)
2) Please separate the two sides xing
screws loose. (+ SCREW DRIVER Use)